EN
4
Operation and Storage Manual of Panel Heater
Environment protection instructions
Obsolete electric appliances contain valuable materials and consequently they
should not be treated as domestic waste! We ask for your cooperation and your
active contribution to protect the resources and the environment. Please submit
your out-of-use appliances to the organized buy-back stations (if there are such).
TABLE 2: INFORMATION REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS
Model identifier(s):
1.CN04 050 MIS F; 2.CN04 100 MIS F; 3.CN04 150 MIS F; 4.CN04 200 MIS F; 5.CN04 250 MIS F; 6.CN04 300 MIS F 230V~ 50Hz
Ite
m
Symbol
Value 1.
Value 2.
Value 3.
Value 4.
Value 5.
Value 6.
Unit
Ite
m
Unit
Heat output
Type of heat input for electric storage local space heaters only (select one)
Nominal heat output
P
nom
0.50
1.00
1.50
2.00
2.50
3.00
kW
Manual heat charge control, with integrated thermostat
[no]
Minimum heat output (indicative)
P
min
0.00
0.00
0.00
0.00
0.00
0.00
kW
Manual heat charge control, with room and/or outdoor temperature feedback
[no]
Maximum continuous heat output
(indicative)
P
max,C
0.50
1.00
1.50
2.00
2.50
3.00
kW
Electric heat charge control, with room and/or outdoor temperature feedback
heat charge control, with integrated thermostat
[no]
Auxiliary electricity consumption
Fan assisted heat output
[no]
At nominal heat output
el
max
0.44
0.91
1.42
1.89
2.41
2.87
kW
Type of heat output/room temperature control (select one)
-
At minimum heat output
el
min
0.00
0.00
0.00
0.00
0.00
0.00
kW
Single stage heat output and no room temperature control
[no]
In standby mode
el SB
0.00
0.00
0.00
0.00
0.00
0.00
kW
Two or more manual stages, no room temperature control
[no]
With mechanic thermostat room temperature control
[yes]
With electronic room temperature control
[no]
With electronic room temperature control plus day timer
[no]
With electronic room temperature control plus week timer
[no]
Other control options (multiple selections possible)
Room temperature control, with presence detection
[no]
Room temperature control, with open window detection
[no]
With distance control option
[no]
With adaptive start control
[no]
With working time limitation
[no]
With black bulb sensor
[no]
TESY Ltd
48 Madara Blvd,
Shumen, 9700,
Bulgaria
Summary of Contents for CN04 YYZ MIS F
Page 6: ...BG 6 3 3 8 3 8 8 a 100 1 100 2015 1188 2009 125 45 3 2 1 2 3 1 volume 1 4 2 volume 2 2...
Page 9: ...BG 9 ON OFF 100W m2 2 50 m 30W m3...
Page 14: ...RU 14 3 3 8 3 8 8 100 1 100 2015 1188 2009 125 EC 45 3 2 1 2 3 1 volume 1 4 2 volume 2 2...
Page 19: ...UA 19 0 5 W m2K 0 35 W m2K 2 5 ON OFF 100 2 2 50 30 3...
Page 26: ...RS 26 ON OFF 100W m2 2 50 m 30W m3...
Page 27: ...MK 27 3 3 8 3 8 8 a 100 1 100 2015 1188 2009 125 45 2 1 2 3 1 volume 1 4 2 volume 2 2...