TESY CH20060IX Instructions For Use And Maintenance Manual Download Page 4

4

       

Instructions for use and maintenance 

EN

CONTENTS OF THE PACKING BOX

The contents of the packaging may vary depending on 
the specific model:

CH 200 60 IX

 •

Range hood CH 200 60 IX

 •

Aluminium filter 

 •

Mounting hook for fixing the chimney bodies 

 •

Installation kit

 •

Instruction manual

 •

Warranty card

 •

Energy label

 •

Product fiche

CH 202 60 WH

 •

Range hood CH 202 60 WH

 •

A set of aluminium filters 

 •

Mounting hook for fixing the chimney bodies

 •

Installation kit

 •

Instruction manual

 •

Warranty card

 •

Energy label

 •

Product fiche

CH 301 60 IX 

 •

Range hood CH 301 60 IX 

 •

A set of aluminium filters 

 •

Mounting hook for fixing the chimney bodies 

 •

Installation kit 

 •

Instruction manual 

 •

Warranty card 

 •

Energy label 

 •

Product fiche 

CHOOSING A LOCATION FOR INSTALLATION OF 
THE RANGE HOOD

When installing the range hood you must observe 
at least 65 cm distance from the range hood and the 
surface on which cookware will be placed. 

Figure 1 – Requirement for minimum distance from the 
working surface

RISK OF POISONING AND DEATH! 
There is risk of poisoning by inhaling the exhaust 

gases. Do not use the appliance simultaneously with 
appliances which generate poisonous gases that are 
released through a chimney, like for example stoves 
running on gas, coal, fuel oil or wood, unless proper 
ventilation has been provided. Such type of heating 
appliances use air for burning at the place of their 
installation and release the exhaust gases through the 
chimney. The air gets sucked out from the kitchen or 
the adjacent room when the range hood operates. This 
generates vacuum unless fresh air flow is provided. In 
this case the exhaust gases are sucked in back from the 
exhaust pipes and fed back into the room. Therefore, 
proper ventilation of the room must be provided.

 RISK OF FIRE! 
Installation of the range hood over an appliance 

which runs on solid fuel (wood or coal) is allowed only 
in case the appliance is permanently assembled. The 
local regulations regarding the mains electricity shall be 
observed. 

If the appliance has not been cleaned in accordance with 
the cleaning instructions it is possible to suck in sparkles 
or other small burning particles and thus to cause fire.

INSTALLATION INSTRUCTIONS

The CH–series chimney-type range hoods are designed 
for wall-mounting. Figure 2 below shows the distances 
for the installation holes.

Summary of Contents for CH20060IX

Page 1: ...CH 200 60 IX CH 301 60 IX CH 202 60 WH EN COOKER HOOD 2 8 Instructions for use and maintenance BG 9 15 www tesy com is a registered trade mark of Tesy ltd...

Page 2: ...dge provided they are supervised or instructed in safe operation of the appliance and understand the related risks Children should not be allowed to play with the appliance Cleaning and user maintenan...

Page 3: ...h if they get deformed will not give access to parts that are charged with voltage Switch on the range hood only after You have placed a frying pan cooking pot or another cookware on the hot plate Oth...

Page 4: ...o not use the appliance simultaneously with appliances which generate poisonous gases that are released through a chimney like for example stoves running on gas coal fuel oil or wood unless proper ven...

Page 5: ...shall be installed in the way specified in the instructions otherwise the appliance may fall OPERATION OF THE RANGE HOOD The accessible parts may get hot while the appliance is operating in combinatio...

Page 6: ...lters come in a pair left and right one and you need to observe their direction during installation Figure 6 Installation method for carbon filters LAMP REPLACEMENT Before replacing the lamp You must...

Page 7: ...OF FIRE RISK OF INJURY In case of damage or unplanned repairs unplug the appliance from the power socket or the fuse and call an authorized service technician Repairs shall be always performed by auth...

Page 8: ...be open The product air inlet is weak Check Carbon filter In products where carbon filters are used the carbon filter must be replaced once ev ery 3 months under normal conditions Does Not Discharge...

Page 9: ...9 BG CH 200 60 IX CH 202 60 WH CH 301 60 IX 3 3 8 3 8 8 220 240 V 50Hz...

Page 10: ...10 BG 65 65 4 Pa 120 150 6...

Page 11: ...11 BG CH 200 60 IX CH 200 60 IX CH 202 60 WH CH 202 60 WH CH 301 60 IX CH 301 60 IX 65 1 CH 2...

Page 12: ...12 BG 2 2 8 140 mm 2 6 3 9 9 5 3 CH 200 60 IX CH 200 60 IX 4 CH 200 60 IX 4 0 I 0 1 2 3 CH 202 60 WH CH 301 60 IX CH 202 60 WH CH 301 60 IX OFF...

Page 13: ...13 BG 5 CH 202 60 WH 5 I 1 II 2 III 3rd III I III CH 3 5 6 5 E14 LED 3W...

Page 14: ...14 BG 1 2 120 6...

Page 15: ...15 BG 220 240V 220 240V 3 3 220 240V 50Hz F CLASS I...

Page 16: ...TESY Ltd Head office 1166 Sofia Sofia Park Building 16V Office 2 1 2nd Floor PHONE 359 2 902 6666 FAX 359 2 902 6660 office tesy com...

Reviews: