Assembly and Operating Manual
Version: AUS 12.12
Assembly and Operating Manual
Version: AUS 12.12
Gas Stop Regulator
Type SOGS38 / SOGSPOL (MD-LGS)
With Integrated Medium Pressure Regulator according to DIN 4811-3
According to VBG D34, Gas Stop regulators are
classified as safety devices. The regulator
protects the integrity of the system in the event
of leakage or damage to the hose and/or its
connections up to the place where connection is
made to the consuming device.
Safety functions of the Gas Stop regulator:
•
Leak test of the Gas Stop hose before start
up of the gas system
By pressing the safety button, testing for leaks
of the Gas Stop hose and its connectors, is
started
•
Testing the Gas Stop hose for leaks during
operation
During operation of the gas system (also during
short interruptions from work), the monitoring
function of the Gas Stop regulator checks the
Gas Stop hose and its connectors for leaks. If
there is the smallest leak, the gas flow is
reliably cut off
•
Protection from damaged Gas Stop hose
If a Gas Stop hose is severely damaged, e.g.
broken, the membrane controlled shut-off
function of the Gas Stop regulator automatically
prevents any continuation of the gas flow,
similar to a hose breakage safety device.
DESIGN
The Gas Stop system is a mechanism which cuts off gas supply in the presence of even minute Gas
Stop hose damages (leak gas quantities). It consists of the actual Gas Stop regulator comprising
monitoring, control and cut-off functions, together with a Gas Stop hose and the respective connectors.
The leak gas safety function works independently of the pressure controller of an intermediate pressure
grade and cuts off the flow of gas to the consuming device in the presence of any leak in the connected
Gas Stop hose and/or its connectors.
Imported and Supplied By:
Address: Unit 1A
107 Carnarvon Street
Silverwater, NSW, 2128
Website: www.tesuco.com.au
Helpline: 1800 631 511
Quality
ISO 9001