Ordering data

Data logger incl. battery and magnet

with

internal external 
°C -

testostor 171-0

0577.1719

°C 

° C or %RH/ °C

testostor 171-1

0577.1715

-

4 x °C

testostor 171-4

0577.1714

%RH / °C

-

testostor 171-3

0577.1713

%RH/ °C, td -

testostor 171-2

0577.1712

%RH/ °C, td -

testostor 1722 

with alarm output

0577.1722

-

%RH/ °C, td or °C

testostor 171-6

0577.1716    

-

4x °C

testostor 171-8

0577.1718

Software English

Comfort Software

0554.0830

Interface

0554.1781

Display module

Without print option

0554.0176

With print option

0554.0175

Temperature probe

Immersion/air probe, 6 m cable

0610.1720

Immersion/air probe, 12 m cable

0610.1721

Air probe (can be directly attached)

0610.1722

Food probe (stainless steel), 2 m cable

0610.2217

Frozen food probe, 2 m cable

0610.3217

Pipe probe with Velcro, 3 m cable

0610.4617

Contact maker, cable length as required

0628.1787

Immersion meas. tip, 500 mm probe pipe, ø 1.5 mm

0600.5792

Pipe probe, for pipe diameter 5 to 65 mm

0602.4592

Exchangeable measuring head for pipe probe

0602.0092

Clamp probe, pipe diameter max. 1“

0602.4692

Magnetic probe, adhesive force approx. 20 N

0602.4792

Magnetic probe, adhesive force approx. 10 N

0602.4892

Thermocouple, fibre-glass, 800 mm, ø 1.5 mm

0602.0644

Thermocouple, fibre-glass, 1500 mm, ø 1.5 mm

0602.0645

Thermocouple, Teflon, 1500 mm, ø 1.5 mm

0602.0646

Humidity/temperature probe

with standard protective cap (plastic)

0636.9717

Accessoris for humidity/temperature probes

Stainless steel sintered cap for measurements in high velocities and 
dirt ingressed air for 0636.9717

0554.0647

Stainless steel sintered cap for measurements in high velocities and
dirt ingressed air for testostor 171-2/171-3

0554.0640

Teflon sintered filter, suitable for measurements in corrosive substances
(for 0636.9717)

0554.0756

Teflon sintered filter, suitable for measurements in corrosive substances
(testostor 171-2/171-3)

0554.0666

Even after the

warranty time has

elapsed

our customer service

will look after you. Send

us your measuring

instrument with a brief

description of the fault.
Include your telephone

number should we

need to contact you.

Warranty from Testo

Dear Customer

Thank you for your confidence in Testo which you have
shown by buying this measuring instrument. You have
made the right choice in choosing a quality product.

The warranty time is

- 2 years for the data logger
- 1 year for the probe

Warranty services do not extend the warranty time.
The warranty and licence agreement for the software are
included in the Comfort Software Instruction Manuals.

The following are not under warranty:

- All working parts such as rechargeable batteries, 

measuring cells, filters, measuring elements etc.

- Fragile parts
-  Damage caused by improper use
- Damage caused by non-adherence to the 

Instruction Manual

- Measuring instruments which have been opened 

after purchase, provided this is not described in the 
Instruction manual for maintenace purposes,

- Instruments in which the serial numbers have been

changed, damaged or removed.

We will repair any faults 

free of charge

if

- it can be proven that they are manufacturing faults
- the faults are reported to us immediately
- the faults are reported to us within the warranty time.

You will be charged for any additional repairs,
adjustments or similar carried out by us and not under
warranty. There is also a charge for transport and
packaging.

Other claims, in particular those for damage occurring
outside the instrument, will not be accepted unless
legally binding.

Summary of Contents for Testostor 171

Page 1: ...testostor 1 17 71 1 Data logger and software module Instruction Manual and Software Description...

Page 2: ...2 On the job Installation 12 Programming the logger Application information 13 Reading the memory Application information 15 Error messages 16 Humidity calibration 17 Adjustment 19 Changing batteries...

Page 3: ...ation The testostor 171 1 171 2 1722 171 3 171 4 and 171 6 logger housings come under protection class IP 65 the testostor 171 0 logger housing comes under protection class IP 68 the testostor 171 8 l...

Page 4: ...trument driver sets up communication between the testostor 171 series and your PC Optimum use of all the functions is only possible with the mouse i e your PC must have two free interfaces COM1 and CO...

Page 5: ...internal 10 to 50 C X 50 to 120 C X X X external Type K TE plug in connection 200 to 1100 C X Type T TE plug in connection 50 to 350 C X Resolution 0 1 C X X X X X X X X 1 C from 250 C X Accuracy in p...

Page 6: ...suring head 0602 0092 Sensor Thermocouple Measuring range 60 to 130 C Short term to 280 C t99 5 s Clamp probe 0602 4692 Sensor Thermocouple Measuring range 50 to 100 C Cable length 1 2 m t99 5 s Magne...

Page 7: ...d to enter licence number see sticker on CD ROM It may be necessary to reboot when installing for the first time Note If the number entered is not accepted check if the caps key is activated if Num in...

Page 8: ...mouse button on the testostor 171 icon and select INSTRUMENT SELECTION If communication between the PC and the data logger has been successful the window opposite appears with the status information...

Page 9: ...ate humidity probe is included with the calibration set which you can attach to the 12 mm probe Screw the probe together with the adapter into the container the standard protective cap should remain o...

Page 10: ...anteed that the logger sensor system and the reference instrument have the same climatic conditions the same temperature is particularly important The humidity containers are not needed for this fine...

Page 11: ...aved measured data is lost the calibration data is saved In case of emergency please contact an authorised service point You can change the battery yourself using the battery set which is available as...

Page 12: ...limit values are exceeded or are not reached acoustically and optically You can call up a table summarizing the number of times the limits have been exceeded by clicking twice in the limit value on t...

Page 13: ...dings The total number of readings to be recorded per channel corresponding to your input for Start and Measuring rate are shown here Battery life The testostor 171 series is equipped with long life L...

Page 14: ...ignal cricket sound be given off when limit values are exceeded Note the relay in testostor 1722 is activated once the limit values are determined in the probe configuration See page 23 The connected...

Page 15: ...me consuming settings START STOP This button starts and stops measurements which were programmed in the Remote controlled starting criteria Every measurement can be stopped via the stop button Descrip...

Page 16: ...tostor 171 2 171 3 0554 0640 Teflon sintered filter suitable for measurements in corrosive substances for 0636 9717 0554 0756 Teflon sintered filter suitable for measurements in corrosive substances t...

Page 17: ...P Tel 19 37 31 58 00 Fax 19 37 31 58 19 testo testo com br BULGARIA Global Test OOD 1408 Sofia Tel 2 9 53 07 96 Fax 2 9 52 51 95 glbl_tst sps bg CHILE ANWO S A Santiago Tel 2 7 31 00 00 Fax 2 2 73 04...

Page 18: ...95 20 Fax 93 753 95 26 info testo es SWEDEN Nordtec Instrument 40241 G teborg Tel 31 704 10 70 Fax 31 12 50 42 nordtec nordtec se SWITZERLAND Testo AG 8604 Volketswil Tel 1 9 08 40 50 Fax 1 9 08 40 5...

Page 19: ...0971 2530 T Ni PC_qxd 08 02 Testo AG Postfach 11 40 D 79849 Lenzkirch Testo Stra e 1 D 79853 Lenzkirch Tel 0 76 53 6 81 0 Fax 0 76 53 6 81 1 00 E Mail info testo de http www testo de...

Reviews: