5 Technical data
5
5
Technical data
Voltage testing
Figures correspond to +23 °C ± 5 °C at <80% rel. humidity. Temperature
coefficient: 0.15 x specified accuracy per 1 °C (<18 °C and >28 °C).
Feature
Values
Voltage range
testo 755-1: 6 - 600 V AC/DC
testo 755-2: 6 - 1000 V AC/DC
Resolution
0.1 V
Tolerance
6 to 49.9 V: ± (1.5% of the display value + 5
digits)
50 to 600 V / 1000 V: ± (1.5% of the display
value + 3 digits)
Frequency range
DC voltage, 14 Hz – 400 Hz
Acoustic
signalling
≥ 50 V AC, ≥ 120 V DC
Voltage detection
Automatic
Polarity detection
Automatic
Range detection
Automatic
Internal load
Approx. 3.5 W at 1000 V
Current
Is < 3.5 mA at 1000 V
Operating time
30 s
Recovery time
240 s
Automatic power on
> 6 V
Reading memory (HOLD)
testo 755-1: 6 - 600 V AC/DC
testo 755-2: 6 - 1000 V AC/DC
Overload indicator
testo 755-1: > = 630 V AC/DC, LC display
shows
OL
testo 755-2: > = 1050 V AC/DC, LC display
shows
OL
Measurement category
CAT III 1000 V / CAT IV 600 V
Single pole phase testing (only testo 755-2)
Feature
Values
Voltage range
>90 to 690 V ± 10% AC voltage to earth
Frequency range
50/60 Hz
Acoustic
signalling
Yes
LED display
Warning symbol
Rotating magnetic field detection (only testo 755-2)
Feature
Values
Voltage range
100 to 400 V ± 10% phase to earth/neutral
Frequency range
50/60 Hz
LC display
L
and
R
Current test
Feature
Values
Voltage range
Max. 200 A AC
Summary of Contents for 755-1