3 Specifications 

 

 

7

 

Measurement 

parameter 

Accuracy 

Response time 

CO

2

 

±300 ppm  

(0 to 4,000 ppm)  
±8 % of meas. val. 

(4,000 to 6,000 ppm) 
±500 ppm. 

(6,000 to 10,000 ppm) 

< 120 s (t90) 

Humidity

1

 

±2.5 %RH (5 to 95 %RH)    

Temperature

1

  ±0.5 °C (+ 1 digit) 

 

 

3.2.3.

 

Other instrument data 

Feature  

Values  

Storage/transportation 

conditions 

-20 to 60 °C/-4 to 140°F 

0 to 95 %RH 

Operating conditions  0 to 40 °C/32 to 104 °F/0 to 95 %RH 
Weight incl. holster 

Approx. 382 g 

Housing material 

ABS 

Dimensions (L x W x 

H) 

190 x 65 x 40 mm 

Protection class 

IP 40 acc. to EN 60529 

Operating time 

Min 10 h measuring time (at 

20 °C/68 °F), mains operation possible 

Display 

Segment display 

Supported printer 

0554 0549/0554 0547 

License acc. to 

EN 50543 

Warranty 

Instrument: 24 months 

Battery: 12 months 

CO sensor: 12 months 

CO

2

 sensor: 12 months 

Warranty conditions: see website 

www.testo.com/warranty 

EC Directive 

2014/30/EC 

 

3.2.4.

 

Bluetooth

®

 module (option) 

•  Bluetooth

®

 type: BlueNiceCom IV 

•  Bluetooth

®

 product note: BNC4_HW2x_SW2xx 

Summary of Contents for 315-3

Page 1: ...testo 315 3 CO CO2 measuring instrument Instruction manual...

Page 2: ...2...

Page 3: ...er instrument data 7 3 2 4 Bluetooth module option 7 4 Product description 9 4 1 Overview 9 4 1 1 Control elements and connections 9 4 1 2 Display 12 4 2 Basic properties 13 5 First steps 13 6 Using t...

Page 4: ...writing standards Represen tation Explanation Note Basic or further information 1 2 Action more steps the sequence must be followed Action a step or an optional step Result of an action Menu Elements...

Page 5: ...mperatures For products with Bluetooth optional Changes or modifications that have been made without the explicit consent of the responsible approval authority may cause the retraction of the type app...

Page 6: ...ndustry The Bluetooth option may only be operated in countries in which it is type approved 3 2 Technical data 3 2 1 Measurement ranges and resolution Measurement parameter Measuring range Resolution...

Page 7: ...to 95 RH Weight incl holster Approx 382 g Housing material ABS Dimensions L x W x H 190 x 65 x 40 mm Protection class IP 40 acc to EN 60529 Operating time Min 10 h measuring time at 20 C 68 F mains o...

Page 8: ...inland FI France FR Greece GR Ireland IE Italy IT Latvia LV Lithuania LT Luxembourg LU Malta MT Netherlands NL Austria AT Poland PL Portugal PT Romania RO Sweden SE Slovakia SK Slovenia SI Spain ES Cz...

Page 9: ...4 1 Overview 4 1 1 Control elements and connections 1 Connection for temperature humidity module optional 2 IR interface record printer 3 CO sensor module 4 CO2 sensor module back 5 Display 6 Keyboar...

Page 10: ...figuration mode Confirms entry next setting Long Reading display current value Opens configuration mode Reading display maximum value minimum value hold value Resets maximum value minimum value hold v...

Page 11: ...n mode Changes option increases value Long Reading display Sets zero point deletes zero point Configuration mode Increases value quickly Short Reading display Prints data Configuration mode Changes op...

Page 12: ...abled Lights up information Flashes error message Differential measurement calibration Flashes adjust CO2 sensor in fresh air CO2 sensor should be adjusted in fresh air after 120 operating hours 2 Mea...

Page 13: ...45 C 32 to 113 F 5 First steps Switching on Connect the humidity temperature module 0636 9725 before switching the instrument on option 1 Switch the instrument on press briefly All segments of the di...

Page 14: ...cancel the function press briefly until the display changes Adjustable functions Ensure correct settings all settings are transferred immediately There is no Cancel function Settings and display of t...

Page 15: ...e carried out on busy roads or in closed rooms Ensure that before and during the calibration adjustment no exhaled air reaches the instrument Before completing the adjustment the instrument should be...

Page 16: ...Hold Max Min testo 315 3 is in measurement view The measuring values for Hold Max Min can be called up for CO and CO2 Temperature and humidity if temperature and humidity module is connected Dew poin...

Page 17: ...en carried out Switch on data transfer press and hold down lights up Data is transferred Please refer to the operating instructions for the relevant testo measuring instrument 7 Maintaining the produc...

Page 18: ...and E290 lights up The current CO2 measuring value is too high for an adjustment Acknowledge the error message with Hold Max Min and carry out the adjustment again in fresh air CO2 measuring value 65...

Page 19: ...ew point measurements be carried out Humidity temperature and dew point measurements are possible with the temperature humidity module accessory The display is illuminated also after the testo 315 3 i...

Page 20: ...ts Description Article no testo 315 3 without Bluetooth incl micro USB mains unit cable USB A USB micro B 0632 3153 testo 315 3 with Bluetooth incl micro USB mains unit cable USB A USB micro B 0632 31...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...0970 3153 en 04...

Reviews: