Questions and answers 
Question Possible 

causes/solution 

E0x

 is displayed 

(instruments with display), 
all status LEDs are flashing 
red 

An error has occurred. 
• 

E01

: configuration unsuccessful. 

• 

E02

E03

E04

 or 

E05

: sensor 

faulty. 

• 

E06

: maximum number of time 

marks set, new time mark cannot 
be set. 

----

 is displayed 

(instruments with display)

 

•  No reading available (after setting 

a time mark) 

• Reading 

invalid. 

Hi

 is displayed 

(instruments with display)

 

Reading is above the measuring 
range. 

Lo

 is displayed 

(instruments with display)

 

Reading is below the measuring 
range. 

En

 is displayed 

(instruments with display)

 

Set time marks function is disabled. 

Err

 is displayed 

(instruments with display)

 

Configuration not possible, 
e.g. because 

Rec

 mode is active. 

 

If you have any questions please contact your local dealer or the 
Testo Customer Service. Contact details can be found on the 
internet: 

www.testo.com/service-contact

 

 

Shop for Data Logging products online at:   

www.

DataLoggerStore

.com   

1.888.610.7664

Summary of Contents for 184 T1

Page 1: ...testo 184 Data logger Instruction manual Shop for Data Logging products online at www DataLoggerStore com 1 888 610 7664 ...

Page 2: ...2 Shop for Data Logging products online at www DataLoggerStore com 1 888 610 7664 ...

Page 3: ...nstrument that is described in the documentation Follow the prescribed steps exactly Use only original spare parts from Testo 1 3 Protecting the environment Dispose of faulty rechargeable batteries spent batteries in accordance with the valid legal specifications At the end of its useful life send the product to the separate collection for electric and electronic devices observe local regulations ...

Page 4: ... T1 T4 no T2 T3 yes Probe type T1 T2 T3 internal NTC temperature sensor T4 internal PT1000 temperature sensor Measuremen t channels 1 internal Measure ment parameters unit Temperature C F Measuring range T1 T2 T3 35 to 70 C T4 80 to 70 C Accuracy T1 T2 T3 0 5 K T4 0 8 K 80 to 35 1 C 0 5 K 35 0 to 70 C Resolution 0 1 C Operating temperature T1 T2 T3 35 to 70 C T4 80 to 70 C Storage temperature T1 T...

Page 5: ... g T2 T3 T4 45 g Directives standards certificates 2014 30 EC EN 12830 HACCP certified temperature calibration certificate traceable according to ISO 17025 Warranty guarantee T1 T2 12 month warranty from the production date production date see circled date code MMDD on the identification plate T3 T4 24 month warranty warranty terms see website www testo com warranty testo 184 H1 G1 Feature Values ...

Page 6: ...inute measuring cycle 25 C G1 120 days 15 minute measuring cycle 25 C Protection class IP 30 Measuring interval 1 minute to 24 hours temperature and relative humidity 1 second acceleration Scan frequency 1600Hz acceleration Memory 64 000 readings temperature and relative humidity G1 1 000 readings acceleration Dimensions 44 x 12 x 97 mm Weight 45 g Directives standards certificates 2014 30 EC HACC...

Page 7: ...sh once every 5 seconds In hibernation mode the status LEDs are disabled Alarm Feature LED colour No alarm green Alarm red Battery Feature LED colour Battery life 10 days green Battery life 10 days red Mode Feature LED colour WAIT mode wait for program start green and red Rec mode measurement program running green End mode measurement program finished red Shop for Data Logging products online at w...

Page 8: ...k xyz measurement axes for acceleration measurement Alarm set limit value s exceeded set limit value s not exceeded 8 Units 9 Battery capacity sufficient empty 10 Lower limit value exceeded 11 Upper limit value exceeded For technical reasons the display speed of liquid crystal displays becomes slower at temperatures below 0 C approx 2 seconds at 10 C approx 6 seconds at 20 C This has no influence ...

Page 9: ...key to toggle between the displays Display sequence max display range per version certain data is not displayed depending on the operating mode Display T2 T3 H1 G1 Current temperature reading C F X X X X Current average value MKT Mean Kinetic Temperature X X X X Current relative humidity reading X X Current acceleration reading X axis x g X Current acceleration reading Y axis y g X Current acceler...

Page 10: ...activated 3 4 Important information and glossary of terms Single use data logger versions T1 and T2 the data logger has a time limited service life which begins from the first time the program is started Start and stop setting the criteria for starting and stopping the program are defined in the configuration file One of the criteria must be selected for starting the program When selecting the cri...

Page 11: ...rature in degrees Kelvin E activation energy standard value 83 144 kJ mol R universal gas constant 0 0083144 kJ mol T1 average temperature in degrees Kelvin during the first time period Tn average temperature in degrees Kelvin during the nth time period MKT activation energy the default activation energy is set at 83 144 kJ mol as recommended in USP 1160 If other estimates are available as a resul...

Page 12: ...ble in XML data format When using the Configuration Assistant some functions are predefined or filled in automatically Expert Mode must be enabled in order to use and manually set all instrument functions 5 Export changes to the configuration by clicking on the button on the data logger A window opens for exporting form data 6 Select the data logger as the storage location Drive TESTO 184 and expo...

Page 13: ...e CFR version 4 3 service pack 2 or later Please consult the relevant software instruction manual 4 2 Measuring Starting measurement Depending on the configuration of the data logger the measurement program is started via one of the following criteria Button Start hold down the START key for 3 seconds Time Start the measurement starts automatically once the configured time has been reached The log...

Page 14: ...is or to further process readings the software testo Comfort Software Professional version 4 3 service pack 2 or later or testo Comfort Software CFR version 4 3 service pack 2 of later is required accessory Please consult the relevant software instruction manual Measurement data output via NFC The data loggers are equipped with an NFC Near Field Communication transmitter This allows instrument dat...

Page 15: ...chnical data for type required into the instrument so that the positive terminal is visible Only use new branded batteries If a partially exhausted battery is inserted the battery capacity will not be calculated correctly 6 Place the battery compartment cover on the battery compartment and close it by turning clockwise Use a coin for this purpose The data logger is in reset mode rSt is illuminated...

Page 16: ...a time mark Reading invalid Hi is displayed instruments with display Reading is above the measuring range Lo is displayed instruments with display Reading is below the measuring range En is displayed instruments with display Set time marks function is disabled Err is displayed instruments with display Configuration not possible e g because Rec mode is active If you have any questions please contac...

Page 17: ...Shop for Data Logging products online at www DataLoggerStore com 1 888 610 7664 ...

Page 18: ...0970 1842 en 03 Shop for Data Logging products online at www DataLoggerStore com 1 888 610 7664 ...

Reviews: