TESTO 0572 2200 Series Instruction Manual Download Page 27

Approval and Certification

The use of the wireless module is subject to the regulations

and stipulations of the respective country of use, and the
module may only be used in countries for which a country
certification has been granted. The user and every owner has
the obligation to adhere to these regulations and prerequisites
for use, and acknowledges that the re-sale, export, import etc.
in particular in countries without wireless permits, is his
responsibility.

Product

Testo Gateway (Wireless Sensors) EU

Mat.-No.

0572 2200 01

Model No.

0572 2200 01

Date

07.06.2022

Country

Comments


EFTA

The EU Declaration of Conformity can be

found on the testo homepage www.testo.com
under the product specific downloads.

EU countries:

Belgium (BE), Bulgaria (BG), Denmark (DK),
Germany (DE), Estonia (EE), Finland (FI),
France (FR), Greece (GR), Ireland (IE), Italy
(IT), Latvia (LV), Lithuania (LT), Luxembourg
(LU), Malta (MT), Netherlands (NL), Austria
(AT), Poland (PL), Portugal (PT), Romania
(RO), Sweden (SE), Slovakia (SK), Slovenia
(SI), Spain (ES), Czech Republic (CZ), Hungary
(HU), Republic of Cyprus (CY).

EFTA countries:

Iceland, Liechtenstein, Norway, Switzerland

WEEE Reg. no. DE 75334352

United
Kingdom
(UK)

The UK Declaration of Conformity
can be found on the testo
homepage www.testo.com under

the product specific downloads

.

-Module

Feature

Values

Radio range

up to 200 m (650 feet)
(free field)

Type

Lierda
L-RFOMD41-04594-02

RF Band

865 to 868 MHz
(L-Band)

Output power

12.5 dBm

Antenna gain

Max. -0.15 dBi

Company

Lierda Science &
Technology Group
Co., Ltd

Product

Testo Gateway (Wireless Sensors) FCC

Mat.-No.

0572 2200 02

Model No.

0572 2200 02

Country

Comments

Canada

Product IC: 6127B-0572220002

See IC Warnings

USA

Product FCC ID: WAF-0572220002

See FCC Warnings

-Module

Feature

Values

Radio range

up to 200 m (650 feet)
(free field)

Type

Lierda
L-RFOMD41-04594-02

RF Band

915 to 928 MHz

Modulation

GFSK

Output power

12.5 dBm

Transm. rate

50 kBit/s

Antenna gain

Max. -0.15 dBi

Antenna Part
Number

0440 3002

Company

Lierda Science &
Technology Group
Co., Ltd

IC Warnings
CAN ICES-003(B)/NMB-003(B):

This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du
Canada.

RSS-Gen & RSS-247 statement:

This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-
exempt RSS(s).
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may
cause undesired operation of the device.

L’émetteur/récepteur exempt de licence contenu dans le présent appareil est
conforme aux CNR d’Innovation, Sciences et Développement économique
Canada applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes :
(1) L’appareil ne doit pas produire de brouillage
(2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.

Caution: Radio Frequency Radiation Exposure
This equipment complies with radio frequency exposure limits set forth by
the Innovation, Science and Economic Development Canada for an
uncontrolled environment.

This equipment should be installed and operated with a minimum distance of
20 cm between the device and the user or bystanders.

Co-Location:
This device must not be co-located or operated in conjunction with any other
antenna or transmitter.

Attention : exposition au rayonnement de radiofréquences
Cet équipement est conforme aux limites d'exposition aux radiofréquences
définies par la Innovation, Sciences et Développement économique Canada
pour un environnement non contrôlé.

Cet équipement doit être installé et utilisé avec un minimum de 20 cm de
distance entre le dispositif et l'utilisateur ou des tiers

Co-location
Ce dispositif ne doit pas être utilisé à proximité d’une autre antenne ou d’un
autre émetteur.

FCC Warnings
Information from the FCC (Federal Communications
Commission)

For your own safety

Shielded cables should be used for a composite interface. This is to ensure
continued protection against radio frequency interference.

FCC warning statement

This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

Caution

Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
Shielded interface cable must be used in order to comply with the emission
limits.

Warning

This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired operation.

Caution: Radio Frequency Radiation Exposure

This equipment complies with radio frequency exposure limits set forth by
the FCC for an uncontrolled environment.

This equipment should be installed and operated with a minimum distance of
20 cm between the device and the user or bystanders.

Co-Location:

This device must not be co-located or operated in conjunction with any other
antenna or transmitter.

Product

产品名称

Testo Gateway (Wireless Sensors) CN
Testo Gateway (Wireless Sensors)

网关

Mat.-No.

料号

0572 2200 03

Model No.

型号

0572 2200 03

Country

Comments

China

Approved

-Module

-

讯模块

Feature

特征与参数

Values

Radio range

线电范围

up to 200 m (650 feet)
(free field /

无障碍场地

)

Type

型号

Lierda
L-RFOMD41-04594-02

RF Band

频频段

868.0 to 868.6 MHz

Company

制造商

Lierda Science &
Technology Group Co.,
Ltd

Product

Testo Gateway (Wireless Sensors) IN

Mat.-No.

0572 2200 06

Model No.

0572 2200 06

Country

Comments

India

Approved

-Module

Feature

Values

Radio range

up to 200 m (650 feet)
(free field)

Type

Lierda
L-RFOMD41-04594-02

RF Band

865 to 867 MHz

Output power

12.5 dBm

Antenna gain

Max. -0.15 dBi

Company

Lierda Science &
Technology Group
Co., Ltd

Summary of Contents for 0572 2200 Series

Page 1: ...eway 0572 2201 XX radio data logger ambient temperature 0572 2202 XX radio data logger temperature product simulation 0572 2203 XX radio data logger door contact 0572 2204 CC radio data logger core te...

Page 2: ...button functions LED 9 4 Commissioning 10 4 1 Mounting on the wall 10 4 2 Mounting of communication module to the Gateway 10 4 2 1 WLAN module and PoE module 11 4 2 2 Power supply batteries 12 4 3 Co...

Page 3: ...y Sensor power supply 21 6 1 Lithium battery 21 6 2 Modified sensors for power supply test 21 7 Technical data 22 7 1 Radio specific data 22 7 2 Technical specifications for WLAN or Ethernet communica...

Page 4: ...that you can refer to it when necessary Please read this instruction manual through carefully and familiarize yourself with the product before putting it to use Hand this instruction manual on to any...

Page 5: ...ors are part of the testo Saveris Solution As a stationary measurement technology solution they are ideally suited for monitoring temperature and door contacts in cold stores and warehouses The wirele...

Page 6: ...customer s WLAN or Ethernet infrastructure is a prerequisite for transmitting the data not part of the scope of delivery The measured values stored in the cloud can be called up and analyzed at any ti...

Page 7: ...verview 3 2 Product description 1 article number name 0572 2201 XX description radio data logger ambient temperature 2 article number name 0572 2202 XX description radio data logger temperature produc...

Page 8: ...article number name 0572 2204 XX description Gateway 6 article number name 0554 9320 01 description WLAN communication module 7 article number name 0554 9330 description LAN PoE communication module...

Page 9: ...lue according a calculated simulated behavior The product simulator is designed to simulate food thawing and chilled or frozen food However the product simulator does not represent the core temperatur...

Page 10: ...t blinking green default off Gateway LED2 Network status Mode action button Signal Color Configuration Mode Config XML is saved and GW connect to Cloud connected to PC via USB cable continuously on gr...

Page 11: ...o OFF Power Off Sleep Mode no connection to Gateway button press 1sec in state sleep Blinking for 90 sec 0 2 sec on 0 8 sec off red sensor in roaming mode In case of finished join mode max 90 sec 1x 2...

Page 12: ...n its functionality and has only the purpose to get measurement values from the IoT data base The UI is simple and limited Measurement and communication cycle is set default by system Measurement cycl...

Page 13: ...4 2 1 WLAN module and PoE module Before connecting the gateway to the PC or to power supply the communication modules must be mounted to the gateway first...

Page 14: ...eway In case of using WLAN make sure that a stable WLAN connection is available before you start configuring the gateway In case of using Ethernet make sure that the Ethernet connection of the Gateway...

Page 15: ...f necessary your WLAN password in the relevant fields on the PDF form 5 Click on the Save configuration button A dialogue box opens for exporting the form data 6 Select the external Gateway drive as t...

Page 16: ...1 2 4 3...

Page 17: ...3 sec Sensor LED is on and Gateway is in connect join mode 2 Press the button on the radio logger for 3 sec in State OFF Blinking for 90 sec 0 2 sec on 0 8 sec off green sensor is in manual join mode...

Page 18: ...5 Software 5 1 Saveris Restaurant Software To get access use following URL address https i food saveris net 5 1 1 Access Please enter your assigned account e mail address and password...

Page 19: ...er website By selecting the Online data logger page you get to the radio data logger and dashboard 5 1 3 Measurement curves Measurement curves can be displayed by pressing the three dots or select pag...

Page 20: ...account you can only display the data To be able to export the data you must switch to the MTS View Software 5 2 MTS Viewer Software URL address To get access use following URL address MTS Viewer save...

Page 21: ...account in parallel 5 3 MTS Viewer dashboard 5 3 1 Selecting Sensor Before displaying the measurement values the relevant sensors must be selected 5 3 2 Display of measurement data To display current...

Page 22: ...ile 5 4 Disable of radio data sensor or Gateway If a Gateway or sensor is connected to the cloud the disconnecting of a sensor or gateway has to be done manually by Testo R D team Testo SE Co KGaA Cel...

Page 23: ...customer If battery is empty the sensor must be replaced 6 2 Modified sensors for power supply test To perform VCC tests Test provides modified sensors Battery is assembled inside but not connected t...

Page 24: ...on 0 1 C 0 1 C 0 1 C Measurement cycle 1 min 24 h 5 min 24 h 5 bis 24 h response time t90 20K 20 min t90 20K 20 min t90 20K 20 min communicati on cycle 1 min 24 h 1 min 24 h 1 min 24 h 1 min 24 h 7 1...

Page 25: ...communicate only to the outside in the direction of the cloud No bidirectional port releases are necessary 7 3 General data sensors Sensors 0572 2201 xx 0572 2202 xx 0572 2203 xx 0572 2204 xx Operati...

Page 26: ...rnal Sensor x x External Sensor x Gateway 0572 2200 xx Operating temperature 0 C 50 C Storage temperature 40 C 60 C Protection class IP 67 with connected WLAN communication module IP 20 with connected...

Page 27: ...the device and the user or bystanders Co Location This device must not be co located or operated in conjunction with any other antenna or transmitter Attention exposition au rayonnement de radiofr qu...

Reviews: