Press the MODE key to switch between modes.
MODE 1
is suitable for measuring the general gas concentration in indoor areas.
The gas concentration is indicated by
the increasing bar display.
MODE 2
is suitable for locating a leak. In this mode, rising or falling
concentration values are output.
At the beginning, two bar segments
are displayed in the middle.
At the same time, the sensor LED
flashes in a colour corresponding to
the concentration value and an audio
signal is emitted at the same
frequency.
As the concentration increases, a
deflection to the right is displayed.
The frequency of the flashing/audio
signal increases.
As the concentration decreases, a
deflection to the left is displayed. The
frequency of the flashing/audio signal
decreases.