Testec TT-SI 7002 Instruction Manual Download Page 11

 

 

 

 

 

 

Man_7002_0919 

          www.testec.de  

    9

 

 

 

 

7 Service & Warranty Information

 

 

 

Limited One-Year Warranty

 

 

Testec Elektronik GmbH warrants these products to be free from defective material 
or workmanship for a period of 1 year from the date of original purchase. Under 
this warranty, Testec Elektronik GmbH is limited to repairing the defective device 
when returned to the factory, shipping charges prepaid, within the warranty 
period.

 

 

Units returned to Testec Elektronik GmbH that have been subject to abuse, 
misuse, damage, or accident, or have been connected, installed, or adjusted 
contrary to the instructions furnished by Testec Elektronik GmbH, or that have 
been repaired by unauthorized persons, will not be covered by this warranty.

 

 

Testec  Elektronik  GmbH  reserves  the  right  to  discontinue  models,  change 
specifications, price, or design of this device at any time without notice and without 
incurring any obligation whatsoever.

 

 

The purchaser agrees to assume all liabilities for any damages and/or bodily injury 
which  may  result  from  the  use  or  misuse  of  this  device  by  the  purchaser,  his 
employees, or agents.

 

 

This warranty is in lieu of all other representations or warranties expressed or 
implied and no agent or representative of Testec Elektronik GmbH is authorized to 
assume any other obligation in connection with the sale and purchase of this 
device.

 

 

Service

 

 

If you have a need for calibration or repair services, technical, or sales support, 
please contact us: 
 

 

    Testec Elektronik GmbH 
    Fritz-Klatte-Str. 6 
    65933 Frankfurt / Germany 
 
    Tel.: +49 (0) 69 – 9433350 
    E-Mail: [email protected] 
    www.testec.de 

 
 
 

 

Summary of Contents for TT-SI 7002

Page 1: ...INSTRUCTION MANUAL TT SI 7002 25MHz active differential probe x20 x50 x200 ...

Page 2: ......

Page 3: ...midity dampness or other environmental conditions that might affect safety Do Not Remove the Probe s Casing Removal of the probe s casing may expose you to electric shock If necessary disconnect the inputs and outputs of the probe before opening the case Hazardous Contact To avoid injury remove jewelry such as rings watches and other metallic objects Do not touch exposed connections and components...

Page 4: ...rking voltage ranges See specifications on page 7 Use Proper Power Source Do not operate this probe from a power source that applies more than the voltage specified Must be Grounded This probe is grounded by the shell of the BNC connector through the grounding conductor of the power cord of the measurement instrument Before making connections to the input leads of this probe ensure that the output...

Page 5: ...hin the test set up Compliance Statements EC Declaration of Conformity The product conforms to the applicable European Union requirements per IEC 61010 031 2015 Safety requirements for electrical equipment for measurement control and laboratory use Part 31 Safety requirements for hand held probe assemblies for electrical measurement and test EU RoHS Compliance The probe and accessories conform to ...

Page 6: ...ndicator LED Initial Inspection This unit is tested prior to shipment It is therefore ready for immediate use upon receipt An initial physical inspection should be made to ensure that no damage has been sustained during shipment After the inspection verify the contents of the shipment Delivery Content Differential probe TT SI 7002 2 x Grabber black red TT SI GR2 2 x test leads with insulated 4 mm ...

Page 7: ...o to x50 and for voltages up to 700 V set the attenuation ratio to x200 4 The power indicator LED should turn on 5 Plug the supplied grips onto the test leads and connect the circuit under test Vertical Scale on Oscilloscope The actual vertical scale of the oscilloscope is equal to the attenuation factor multiplied by the range of vertical scale selected on the oscilloscope For example with the pr...

Page 8: ... 6 Over Range Indicator Red Attenuation Selector Switch Power Indicator Red Probe Input 2 x 4mm Plug External Power Supply Probe Output BNC Connector 3 Product Overview Included Accessories TT SI NT7 TT SI TL7 TT SI GR2 TT SI BN7 ...

Page 9: ...tage each side to ground 600 Vrms Input Impedance differential 4 MOhm 1 2 pF Input Impedance each side to ground 2 MOhm 2 3 pF Output Voltage Swing 8 V using 1 MΩ oscilloscope input Offset typical 5 mV Noise typical 2 mVrms Source Impedance 50 Ohm Power Supply 9 V power adapter included Weight 250 g Dimensions 195 x 55 x 30 mm BNC cable length 100 cm Input lead length 55 cm each Operation Tempearu...

Page 10: ...I 7002 Derating Curve 6 Cleaning This probe does not require any particular cleaning If necessary clean the case with a soft cloth WARNING Dry the probe thoroughly before attempting to make voltage measurements CAUTION Avoid immersing or using abrasive cleaners or solvents containing Benzene or similar solvents on the probe as these can cause deterioration of the probe body and cables ...

Page 11: ...t be covered by this warranty Testec Elektronik GmbH reserves the right to discontinue models change specifications price or design of this device at any time without notice and without incurring any obligation whatsoever The purchaser agrees to assume all liabilities for any damages and or bodily injury which may result from the use or misuse of this device by the purchaser his employees or agent...

Page 12: ...robe User s Manual 2019 TESTEC Elektronik GmbH All rights reserved Unauthorized duplication of TESTEC documentation materials is strictly prohibited Customers are permitted to duplicate and distribute TESTEC documentations for internal educational purposes ...