Operation
34 Testboy
®
TB 313
AC voltage measurement / V~
Use the selector switch to set the appropriate range. Insert the black test
lead into the ‘COM’ socket and the red test lead into the V/
Ω
/TEMP/CAP
socket. Using the test probes, touch the test points of the test object. Read
measurement value on the display.
AC voltage
Measurement range
Resolution
Accuracy
200 mV
1 mV
± 1.2 % of r 5 digits
2 V
0.001 V
20 V
0.01 V
200 V
0.1 V
± 1 % of r 5 digits
600 V
1 V
± 1.2 % of r 5 digits
-Input resistance: 10 M
Ω
Max. input voltage range of 200 mV to 250 V
Max. input voltage: 600 V AC RMS, frequency range: 40-400 Hz
Summary of Contents for TB 313
Page 1: ...Testboy TB 313 Version 1 0 ...
Page 22: ...Technische Daten 22 Testboy TB 313 ...
Page 42: ...Technical data 42 Testboy TB 313 ...
Page 62: ...Caractéristiques techniques 62 Testboy TB 313 ...
Page 82: ...Dati tecnici 82 Testboy TB 313 ...
Page 102: ...Datos técnicos 102 Testboy TB 313 ...
Page 122: ...Dados técnicos 122 Testboy TB 313 ...
Page 142: ...Technische gegevens 142 Testboy TB 313 ...
Page 143: ......