NIC init err -

NIC Rx overrun -

NIC Tx timeout

No IP address -

Packet Rcv Err -

PING Test Detailed Status Messages -

IP add = DNS add

IP add = Rtr add

No ARP Response -

No PING Response -

No Rtr Response

No Router IP

Rtr must be on MyIP LAN segment

Voltage Found, SEL Jack ID

.

Enet Pwr source Found = xV

The Ethernet interface chip used in the LanScaper™ reported a problem to the CPU

during internal initialization. May be caused by a hardware problem inside the tester.

The Ethernet interface chip used in the LanScaper™ provides internal buffering

for multiple packets. If new packets are received faster than they can be processed, the Ethernet
chip discards the new packets and sets the Overrun error flag. The tester detects and reports this
error. May be caused by excessive broadcast traffic on the LAN, or by externally generated packets
addressed to the tester's IP address.

- The Ethernet interface chip used in the LanScaper™ was not able to transmit a

packet within the time allowed. May be caused by a hardware problem inside the tester, a problem
with the attached cable, hardware problems with the connected device, excessive LAN traffic or
collisions on the LAN.

The DHCP server responded to the tester DHCP request, but did not provide an IP

address for MyIP.

An Ethernet packet was received by the LanScaper™ with errors in the header or

packet data. May be caused by excessive signal noise on the Ethernet cable or a hardware problem
with the device transmitting to the tester.

these messages may be displayed when the SEL button is

used to access the status details during active PINGing.

- The active Target IP address is the same as the DNS Server IP address, so

the Target PING is automatically disabled.

- The active Target IP address is the same as the Router IP address, so the

Target PING is automatically disabled.

The IP address active for this conversation is being ARP'ed but is not

responding. The IP address may be unused, the device may be powered off or not connected.

The IP address active for this conversation is not responding to PING

requests. If the addressed device is on the LAN segment, it may be powered off or not
connected. If the addressed device is remote, it may be inaccessible due to WAN problems, it
may be powered off or the device at the Router IP address may not be forwarding the PING
packets.

- The IP address is off the LAN, requiring the PING to go through the Router,

but the Router IP address is not responding to ARP.

- The DHCP server did not provide an IP address for the Router

- Displayed in Setup while setting the Manual Router IP

address. The LanScaper™ requires that the Router be at an IP address on the LAN segment as
defined by the Netmask and MyIP addresses. Setup will not allow the Router IP address to be set to
an off-LAN address.

- The tester does not operate in Network modes when voltage, and

possibly destructive power, is found. Voltages found will terminate the test in progress and the only
option is to run the Jack ID test (by pressing SEL). The only exception to this is the possibility of
an Ethernet power source providing power between the 1-2 and 3-6 pairs. In that case, the
following message will be displayed

- Some devices provide power for IP-phones or wireless

transceivers on the same wires that carry the Ethernet data signals. They do this by connecting a
voltage to the center-taps of each transformer in their Ethernet interface. The LanScaper™ reports
this and allows the Network testing to continue.

Summary of Contents for LanScaper NT700

Page 1: ...LanScaper TM OPERATING INSTRUCTIONS...

Page 2: ...test change the value of an option enter sub menus or move to the next screen Depending on context Mode Key Press CABLE for cable modes press NTWRK for network modes or press the center both at once...

Page 3: ...Jack ID 3 2 2 Cable Test 3 2 3 Cable Length 3 2 4 Tone Generator 3 3 Network Test Modes 3 3 1 Flash Link LED 3 3 2 PING Test 3 3 3 Validate Link 4 0 SETUP MODE 4 1 Target Setup Sub Menu 4 2 PING Setu...

Page 4: ......

Page 5: ...d Skips the ID portion of the Jack ID test above 1 Connect one end of cable run to be tested to LanScaper Press CABLE button repeatedly until Cable Test is displayed twice if unit was off Press SEL bu...

Page 6: ...2 Press NTWRK button repeatedly until PING Test is displayed on screen two presses when off Press SEL button to enter test Several status screens will be displayed while establishing a link and negot...

Page 7: ...button will immediately end any currently running task and either begin the executing the first task of a new category cable or network or display the next mode in the same category waiting for a pre...

Page 8: ...detected the second line will have a flashing x in that position and the specific short condition displayed on the third line If a split pair is detected those pin positions on the second line will b...

Page 9: ...tion modes The address configuration mode is a setup option In either case a Target device must be selected in Setup and its IP address confirmed If the Target address is on the LAN segment as determi...

Page 10: ...tester for it to be possible for them to communicate directly on the same LAN segment A good guess is to use an IP address different by just a few low order digits in the low order byte of the IP add...

Page 11: ...ne The Target IP address can either be on the LAN segment or remote If the Target is on the LAN the status of the LanScaper Target conversation will be as described for the Router above In the off loc...

Page 12: ...ll assume is not responding on the network it will not interfere with other devices on the LAN The PING Generator must be setup in DHCP Off mode and its manual IP configuration must be setup to addres...

Page 13: ...on reserved IP addresses This is any address other than 0 0 0 0 or 224 255 x x x MyIP is edited in a similar fashion to the Target IP addresses described above The Router IP address is also edited in...

Page 14: ...th it measures in feet or meters The length constant is converted to the new units In Validate Link mode this status shows that the tester has detected another active LanScaper trying to start a PING...

Page 15: ...ame as the DNS Server IP address so the Target PING is automatically disabled The active Target IP address is the same as the Router IP address so the Target PING is automatically disabled The IP addr...

Page 16: ...the correct pins at the other end of the cable While testing with a remote the wire map shows the pin numbers line 1 main line 2 remote A is a special case of a miswire in which the pair is wired to...

Page 17: ...8 8 8 8 8 8 8 8 SHORT T568A B Passing Cable unshielded 1 not twisted with 2 3 not twisted with 6 Fig 6 1 Examples of Wiring Errors shielded 12345678S ID 12345678S ID 12345678 ID 12345678S ID 12345678S...

Page 18: ...rature 0 to 50 C 32 to 122 F Storage temperature 30 to 80 C 20 to 176 F Humidity 10 to 90 non condensing 9V Alkaline battery typical times are for the full capacity of the battery used continuously in...

Page 19: ...an be used with a straight through cable to connect a normal HUB port to the UPLINK port Ethernet physical wiring is done on a point point mechanism but an Ethernet network is a star network where any...

Page 20: ...ound on and once it has determined that it only forwards traffic destined for that address to that port This allows for fewer collisions on the LAN by not re transmitting every packet on every port Mu...

Page 21: ...ng PINGing the DNS server proves that the LanScaper can access a device on the WAN Router see below Internet Protocol Actually TCP IP Transmission Control Protocol Internet Protocol but commonly abbre...

Page 22: ...munications which differentiates it from a HUB or switch A hardware box sold as a router will usually include a HUB or switch chip inside providing a convenient connection point for multiple Ethernet...

Page 23: ...inspected by anyone other than Test Um authorized personnel In no event will Test Um Inc be liable for any incidental or consequential damages The LanScaper is designed and manufactured to provide tr...

Page 24: ...Test Um Inc The Intelligent Test Solutions Company 805 383 1500 FAX 805 383 1595 www test um com 808 Calle Plano Camarillo CA 93012 TU9854 3 Rev A 2 03...

Reviews: