5. MAINTENANCE
Periodically check the consistency of the brake pad.
The equipment does not need any lubrication, as the wheels are equipped with waterproof
bearings.
5.1 HYDRAULIC CIRCUIT MAINTENANCE (motorised version mod. CRT160)
a)
Change the hydraulic oil after 500 working hours and, thereafter, every 1500 hours (or in
any case every year).
b)
To discharge the exhaust hydraulic oil, use the suitable tap in the tank.
DANGER: let the hydraulic oil be completely cooled before removing it and always use
the suitable safety wears (gloves, etc.).
ATTENTION: the discharge of the exhaust oils has to be effectuated in conformity with
the laws in force in the relevant country.
c)
Fill the oil in the tank by means of the suitable filler (table 1, pos. 12).
ATTENTION: make maximum care when filling to make sure no foreign matter, which
could cause irreparable damages to the circuit’s components, enters along with the oil; if
possible filter the oil with a 10
µ
m filter.
d)
Replace the filter cartridge (table 1, pos. 14) after 500 working hours and, thereafter, every
1500 hours (or every year at least)
For further maintenance operations of installed hydraulic components (pumps and motors)