background image

 

2/8 

COPYRIGHT NOTICE

 

 

No part  of this document  may be reproduced, republished, translated or digitalized in any form or by 

any means, without prior written permission of TESLA. 

Information contained in this manual relates exclusively to the TERA system component specified on the 

title page. New versions and modifications may be developed without prior notice to current users. TESLA 
has made every attempt to provide you with complete, error-free and accurate information in this manual. 
TESLA is not liable for errors or omissions contained in this document, or for any damages however resulted 
from using or relying on any information contained herein. TESLA's liability for errors shall be strictly limited 
to correcting such errors and providing advisory services as described below. 

Users should be familiar with operation basis of used product. If you experience any problems with your 

product, please contact us at: 

TESLA 

Rubeska 215/1 

190 00 Prague 9 - Vysocany 

www.tesla.cz

  

 

1

 

Introduction 

This  document  describes  technical  specifications  and  user  operation  of  the  TSR4  WLAN  Wireless  and 

USB Radon Probe.  

Product  was  developed  and  manufactured  in  the  Czech  Republic.  All  rights  reserved  TESLA.  Offer  or 

delivery of products or services related to the product does not include transfer of ownership rights. 

Before  using  the  product,  please  read  this  manual  carefully  and  understand  all  operating  and  safety 

precautions. Compliance with operational and safety precaution can prevent from damage to equipment or 
injuries to personnel. Operating and safety instructions in the document are marked as follows: 

Attention! 

 

This formatted text indicates the operating and safety instructions. 

The product may only be used in the specified manner and for its intended purpose. The product may 

be provided to third persons along with this documentation only. 

 

2

 

Description and Utilization 

 

 

Summary of Contents for TSR4

Page 1: ...cal Specifications Operation Manual v 1 2017 Table of Contents 1 Introduction 2 2 Description and Utilization 2 3 Scope of Delivery 5 4 Product Specification 6 5 Operating Instructions 6 6 Basic Maint...

Page 2: ...d product If you experience any problems with your product please contact us at TESLA Rubeska 215 1 190 00 Prague 9 Vysocany www tesla cz 1 Introduction This document describes technical specification...

Page 3: ...battery power portable radon measuring probe supports flexible placing options within monitored structures Accumulator will last for more than 1 year after full charging After switching on TSR4 immedi...

Page 4: ...on and on the basis of measured set concentration level value it sends command to actuator wireless actuator or actuator in central unit can be use which is hardwired with power relay Power relay swit...

Page 5: ...ords Quicker download data from probes if you download data after end of the measurement Possibility of various identification writing into internal memory of probe Compatibility TSR4 and TSR3 radon p...

Page 6: ...n 18 2 hours Records saving interval probe 1 255 minutes default 1 hour Results memory capacity in probe 4096 150 days of 1 hours records Powering internal rechargeble accumulator charging via USB Acc...

Page 7: ...way of radon probe If the probe is used for autonomous measurement and data downloading via USB interface then the setting and configuration are realized by usbRADONview application UsbRADONview appl...

Page 8: ...n of Conformity will be delivered by Tesla producer on request If interested please use contacts on the web www tesla cz 8 Repairs Any repairs and non basic maintenance must be performed exclusively b...

Reviews: