background image

 
 
 

 

5/6 

Power supply: 

According to operation method of device can be supplied: 

1)

 

By  internal  accumulator  for portable  use 

  Device  includes  internal  accumulator  which  is able  to 

ensure autonomous operation of device for more than 12 months without charging.  Depends on 
frequency  of  wireless  data  retransmiting  and  depends  on  climatic  condition  of  device  use. 
Accumulator is charged  over USB port and over provided USB cable. The USB cable is possible to 
connect  to  PC  or  to  delivered  power  adapter.  Status  of  accumulator  and  charging  process  are 

described in paragraph ´Basic Maintenance/Accumulator charging´ 

 

2)

 

By mains power supply 230V/50Hz for stationary use 

 Device is permanently supplied by delivered 

power  adapter  230VAC/5VDC.  Power  adapter  is  connected  to  device  via  provided  USB  cable.  In 
case of blackout the internal accumulator ensures UPS function. 

 

 

Configuration:  

Setting and configuration of Repeater and whole measuring system is realized by Central Unit connected 

to  PC  and  TERAview  application.

 

Central  Unit  is  not  included  with  package  of  TRR3  and  it  is  sold  and 

delivered extra; see

 

http://www.tesla.cz/

. 

TERAview application, drivers and user manual with detail configuration description is free downloaded 

on website: 

http://www.tesla.cz/

. 

For  successful  repeater  configuration  in  measuring  system  it  is  necessary  to  know  repeater  radio 

channel  number  (communication  wireless  channel)  and  P2P  address  (identification  in  wireless  net).  Both 
parameters are printed out on repeater serial number plate. Repeater radio channel number is possible to 
change by TERAview application and it must be identical to central unit radio channel number. P2P address 
is  permanent  and  it  occur  in  one  big  wireless  net  only  once.  Only  P2P  address  of  Central  Unit  can  be 
identical to P2P address of other elements in network. 
 

6

 

Basic Maintenance 

Accumulator charging: 

   During  portable  use  of  device  is  essential  to  monitor  state  of  internal  accumulator  and  recharge  it  if 
necessary. If accumulator is discharged the device automatically turns off.  
   Current state of accumulator can be determined by these ways: 

1) 

By LED diode ´STAT´

 - If LED starts blinking in yellow color it indicates low voltage of accumulator. 

(see paragraph “Operation Manual / LED diode “STAT””) 

 

2) In TERAview application - where you can check current accumulator voltage.  Voltage should not 
fall below 3.5 V, in limit conditions falls below 3.3V. 

Accumulator  is  charged  via  USB  port  using  supplied  USB  cable.  USB  cable  can  be  connected  to  PC  or  to 
supplied power adapter. Connect USB  cable  with power to USB port  of  device

. LED diode ´CHRG´ n

ext to 

USB port of device indicates charging status according to following chart: 

 

LED diode ´CHRG´

 

Color 

Description 

Green 

Accumulator is fully charged 

Yellow 

Accumulator is being charged 

Green 

Yellow

 

alternate blinking

 

Accumulator is damaged, contact Service Center 

No light, No blinking 

It is not connected to an external power supply or device is damaged. 

 

Accumulator is fully charged when LED diode ´CHRG´ is green. You can disconnect USB cable.

 

 

7

 

Repairs  

Any repairs and non basic maintenance must be performed exclusively by Tesla manufacturer. 
    