TI3000 GPU-24 UAV
13
3
Operating Procedures
Figure 3.7.2 – AC Input Connector wiring diagram
AC Hot
Pin “K”
AC Neutral
Pin “M”
AC Ground
Pins “J,L”
3.7 – Normal Function Test Procedures
This section involves “normal function” test proce dures, and includes
steps necessary to ensure that the unit is operating within specified para-
meters prior to use. A digital multimeter (an example is shown in Figure
3.7.1) capable of measuring dc and ac voltage and resistance will be
required to perform some of the tests. These functional test procedures
should become routine.
Check Unit for Evidence of Damage
Check for dents, punctures, case distortion or misalignment, and cracked
or loose connec tors. If no damage is evident, proceed to the next step.
If damage is evident, contact Tesla™ Industries, Inc.
Figure 3.7.1 – Digital Multimeter
C-Negative
Figure 3.7.3 – DC Output Connector wiring diagram
A-Ground
B-Positive