Troubleshooting & FAQ
Fault
Possible Cause
Remedy
7. Circuit breaker continuously trips
Unit is overheating.
A.
Disconnect unit from AC input and DC
A.
output.
Switch breaker to ON position.
B.
Reconnect unit to cables and run.
C.
If LEDs still do not illuminate, Please
D.
contact Tesla™ Customer Service at
(302) 324-8910.
8. Unit does not put out 14.25 volts DC
power.
Unit is not plugged in.
A.
Plug unit into AC power source to
A.
maintain 14.25.
Stand alone Vdc is 12 Volts (unplugged).
B.
9. Unit stand alone voltage is less than
12 volts.
Cells discharged.
A.
Plug unit into AC power source.
A.
Recheck capacity after 25 minutes.
B.
Failure to hold above 12 Vdc, Please
C.
contact Tesla™ Customer Service at
(302) 324-8910.
10. Unit weakens after first start.
Weak cells.
A.
Allow between 30 to 60 seconds
A.
backcharge between uses.