background image

The Wall Connector includes a feature

whereby Wall Connector to Wall Connector
communication allows you to split the

maximum available load over a maximum of 4
Wall Connectors. The wire used for this local
network must share the main power cable

conduit or be housed in a separate conduit.

You can connect the Wall Connectors in series
in a daisy chain configuration.

Note: Take additional precautions into

consideration to prevent water ingress at the
Wall Connectors when installing them

outdoors.

Note: Consult with an electrician to ensure

that the installation meets local regulations.

Daisy Chaining Multiple Wall

Connectors

Each Wall Connector has one terminal block
dedicated for the communication wiring as
shown below. The left hand side of the
terminal block is the input terminal and the
right hand side the output terminal.

1.

Form a daisy-chained network by

connecting the cables from OUT to IN and

always from positive to positive and
negative to negative between each of the
participating Wall Connectors (refer to 

Example of the Communication Wiring on
page 30).

The signal wires between each Wall
Connector should run in signal
conduit. Use a 1/2" (13 mm) UL
approved conduit hub to seal the
signal conduit opening.

If the signal wire is routed in the
power conduit with the power wires,
the insulation rating of the signal wire
should be equal to or greater than
that of the power wires.

The maximum distance between Wall
Connectors is 49 ft (15 m).

Use twisted pair cable for the signal
wire.

Note: Tesla recommends that you use a
shielded cable to limit potential
interference.

2. Set one Wall Connector as the master by

setting the Rotary Switch Position from 1
to 8 depending on the maximum available
output current. Set up to 3 Wall
Connectors as slaves by setting the Rotary
Switch Positions to F. In the load sharing

network, only one unit can be designated
as the master (refer to Set the Operating
Current on page 21).

3. Confirm that the load sharing network is

properly installed by observing the LED
indicators in the Wall Connector. When

starting up the circuit breaker for the first
time, Green lights turning ON for 5
seconds indicate a proper installation as
follows:

Green
Lights

Yellow
Light

Red
Light

What it
Means...

On (top
and
bottom)

Off

Off

Master
unit

On
(bottom)

Off

Off

Slave unit

Appendix B: Optional Connection for Load Sharing

Appendix B: Optional Connection for Load
Sharing

29

Summary of Contents for 1069742-00-A

Page 1: ...WALL CONNECTOR 80A SINGLE PHASE INSTALLATION MANUAL THIS MANUAL IS OF THE HIGHEST IMPORTANCE Approved Markets North America Japan...

Page 2: ...Location for the Wall Connector 10 Installation Considerations 11 Check the Box Contents 13 Step by Step Installation Instructions 15 Tools and Materials Required 15 Overview of Installation Steps 15...

Page 3: ...nersmanualfeedback teslamotors com Copyrights and Trademarks All information in this document is subject to copyright and other intellectual property rights of Tesla Motors Inc and its licensors This...

Page 4: ...ser serviceable Contact Tesla for any repairs or modification Warning When transporting the Wall Connector handle with care Do not subject it to strong force or impact or pull twist tangle drag or ste...

Page 5: ...not use cleaning solvents to clean any of the Wall Connector s components The outside of the Wall Connector the charging cable and the connector end of the charging cable should be periodically wiped...

Page 6: ...36A 32A 28A 24A 20A 16A 12A Frequency 50 to 60 Hz Cable Length 8 5 2 6 m and 24 7 4 m Wall Connector Dimensions Height 15 0 380 mm Width 6 3 160 mm Depth 5 5 140 mm Top Entry Bracket Dimensions Heigh...

Page 7: ...minutes before trying to charge This process repeats 4 times and if all attempts are unsuccessful power is removed and no further attempts are made In this case you will see a red error light on the...

Page 8: ...or contact Tesla for assistance Caution The two phases used must each measure 120V to neutral Earth ground must be connected to neutral at only one point usually at the breaker panel Caution If a 240...

Page 9: ...ta connection one leg must be center tapped and only the two phases on either side of the center tap can be used The two used phases must each measure 120V to neutral Consult the transformer manufactu...

Page 10: ...d N 277V 480V 277V L1 NEUTRAL L3 NOT USED L2 NOT USED GND Caution The unused legs L2 and L3 in the illustration must remain open Do not connect to neutral or to earth ground Caution The center point o...

Page 11: ...1 The circuit breaker should be rated for the continuous current of 12 16 20 24 28 32 36 40 48 56 64 72 and 80A Choose the Best Location for the Wall Connector Determine the parking location of the ve...

Page 12: ...it is used as the standard term for the protective tubing that houses the service wiring In regions where conduit is not used Europe for example a cable comprised of service wiring enclosed in a prote...

Page 13: ...Top Entry Planning Your Installation 12...

Page 14: ...12 13 14 Item Description Quantity 1 Wall Connector 2 Top entry bracket 3 Low profile bracket 4 Low profile bracket screws 2 5 Bottom or rear entry power conduit plug 6 Bottom or rear entry signal con...

Page 15: ...ottom bracket to housing screws 2 13 Top bracket to housing screws 2 14 Top entry bracket mounting screws 2 Items used in only top entry installations Items used in only bottom or rear entry installat...

Page 16: ...ication cable for a maximum of 49 ft 15 m between Wall Connectors Note Tesla recommends that you use a shielded cable to limit potential interference Level Machine drill Overview of Installation Steps...

Page 17: ...using rear entry conduit use at least one set of the edge mounting holes so that the conduit does not interfere with the wall stud If using bottom entry conduit use the center two mounting holes Note...

Page 18: ...nsure that the minimum and maximum height of the bracket is carefully selected It should be installed out of the way of any reasonably foreseeable impacts 2 Optional There are two additional mounting...

Page 19: ...Do not allow the sealing cover to hang from the ribbon cable Doing so can damage the ribbon cable or its connectors 3 For top entry configuration install the wiring to the terminal block in the top en...

Page 20: ...NO VOLTAGE is present at the service wiring or terminals 2 For top entry installation pull the service wiring into the top entry bracket or the Wall Connector Use a 1 25 mm cable gland to seal the pow...

Page 21: ...proper operation verify that neutral is connected to the neutral line inside the circuit breaker box or the main electrical panel 5 Tighten the terminal block to the recommended torque 35 in lb 4 0 N...

Page 22: ...nt setting supported by your circuit breaker Typical circuit breaker ratings are 15A 20A 25A 30A 35A 40A 45A 50A 60A 70A 80A 90A and 100A Use a small flathead screwdriver to adjust the rotary switch t...

Page 23: ...cover to the housing 4 Close any unused openings with power and signal conduit plugs Note There should not be any visible openings to the inside of the Wall Connector and the Wall Connector should be...

Page 24: ...g lights 2 flashes Off Not applicable Charging current is reduced due to high temperature detected in the wall plug or on the input terminals to the Wall Connector If a wall plug is used make sure tha...

Page 25: ...ctrician for proper grounding at your circuit breaker or power distribution box and for proper connection to the Wall Connector Off Off 3 flashes No Input miswired possibly Line and Neutral are swappe...

Page 26: ...o Non Tesla vehicle attempting connection to non compatible input distribution Compatible input distributions are single phase distribution or 400V three phase distribution Top light on Off 3 flashes...

Page 27: ...to reset the Wall Connector to return to proper operation 1 Press the RESET button for two to three seconds When the top light changes from RED to GREEN release the RESET button In this reset method...

Page 28: ...Questions United States and Canada charginginstallation teslamotors com 1 650 681 6133 Mexico charging_mx teslamotors com 1 877 798 3752 Troubleshooting Troubleshooting 27...

Page 29: ...ecure the sealing cover by installing only the top screw 6 Turn ON the circuit breaker 7 Watch for any Red LEDs to be ON after a sequence of LED display if so there is a fault in the installation 8 Li...

Page 30: ...each Wall Connector should run in signal conduit Use a 1 2 13 mm UL approved conduit hub to seal the signal conduit opening If the signal wire is routed in the power conduit with the power wires the...

Page 31: ...MASTER Wall Connector 2 SLAVE Wall Connector 3 SLAVE Wall Connector 4 SLAVE 8 Rotary Switch D D D D In Out F Rotary Switch D D D D In Out F Rotary Switch D D D D In Out F Rotary Switch D D D D In Out...

Page 32: ...the environment or an act of God including but not limited to fire earthquake water lightning and other environmental conditions General appearance or damage to paint including chips scratches dents a...

Page 33: ...ade by Tesla in its sole discretion To the maximum extent permissible under local law Tesla hereby disclaims any and all indirect incidental special and consequential damages arising out of or relatin...

Page 34: ...e expiration of the applicable warranty period provided you sent written notice to Tesla of the alleged defect was brought to the attention of Tesla during the applicable warranty period To initiate a...

Page 35: ...program administered by NCDS The dispute settlement program may be changed at any time without prior notice Contact NCDS at the above listed address or phone number for the most current information c...

Page 36: ...for top entry wiring 17 information about 2 planning your 7 preparing for 18 tools and materials required 15 torque recommendations 19 installation overview 15 installation testing 28 L lights diagnos...

Page 37: ...ension and spacing 11 example of the service wiring 19 wiring installing the top entry bracket for 17 trademarks 2 troubleshooting 23 26 27 29 W wall connectors checking the box contents 13 connecting...

Page 38: ...t t rF P N 1069742 00 A...

Reviews: