II. INTRODUCTION 

 

Thank you for selecting this uninterruptible power supply (UPS). To choose the T-100 series as your 
equipment protector was a wise investment. It includes many features to protect your critical equipments. 
 
The T-100 series UPS system is connected between mains and critical loads, such as computer systems, 
telecommunication systems, computerized instruments etc.  

 

The advantages of using UPS: 
 

 

Increased power quality: 

The UPS has its own internal voltage and frequency regulator circuits which ensure that its output is 
maintained  within  close  tolerances  independent  of  voltage  and  frequency  variations  on  the  mains 
power lines. 

 

 

Increased noise rejection: 

By rectifying the input ac power to dc power, and then converting it back to ac, any electrical noise 
that may present on the input mains supply line is effectively isolated from the UPS output, therefore 
the critical load sees only clean power. 

 

 

Power blackout protection: 

If the mains power fails, the UPS continues to power the critical load from its battery source, leaving 
the load immune from power disturbances. 
 
 

2.1 System Description 

 
Features : 

 

On-line

 technology with pure 

sine wave

 output. 

  PWM and IGBT technology. 

  Microprocessor controlled main controller board. 

  Static (STS) and maintenance by-pass. 

  LCD (Liquid Crystal Display) display.  

  Alarm history ( Memory for max. 64 alarms. ) 

  Automatic battery testing (optional). 

  High quality maintenance-free lead-acid type batteries. 

  High nonlinear load capacity, special for computers. 

 

Accessories :

 

o

  Optional UPS monitoring software ( T-MON, RUPS

 

, RUPSII

 

, UPSILON 2000

 

) SNMP 

devices, compatible to any operating system. 

o

  Remote Monitoring Panel (RMP) available : You can observe the UPS status and parameters 

without using a computer at a remote location up to 200 meters away ( via RS485 interface). 

 

o

  UPS Port Sharer available  

 
T-100 Series Uninterruptible Power  Supplies (UPS) are advanced true On-Line  Sine  wave devices  with 
static transfer switch which provide reliable, regulated, transient-free AC power to sensitive equipment.  
 
Since  the  UPS  is  a  true  On-Line  system,  conditioned  power  is  provided  continuously  to  the  connected 
equipments.  Unlike  standby  power  systems,  the  UPS  is  constantly  regulating  and  filtering  the  output 
power. When incoming power is interrupted, the UPS protects the computers instantaneously without any 
transfer time. 
 
The T-100 Series

 

has high non-linear load capability (i.e. Crest Ratio 3:1) and this is suitable for powering 

special loads such as switching power supplies or highly capacitive inputs like computers. 
 
The  system's  static  transfer  switch  (STS)  provides  by-pass  power  as  its  standby  source.  During  an 
overload condition, the S.T.S will switch the customer's load over to the bypass line with no interruption. 
The S.T.S will transfer back to the inverter automatically when the overload condition has been cleared. If 
the inverter fails internally, the unit switches to bypass within a few milliseconds.  
 
 

Summary of Contents for T-100 Series

Page 1: ...USER MANUAL T 100 SERIES UNINTERRUPTIBLE POWER SUPPLIES 1 Phase Input Output T 102 2 kVA T 103 3 kVA T 106 6 kVA T 107 7 5 kVA T 110 10 kVA T 115 15 kVA...

Page 2: ......

Page 3: ...pted 10 4 4 Operator Control Panel 10 4 4 1 Push buttons 10 4 4 2 First message Up line of the LCD 11 4 4 3 Second message line of the LCD 12 4 5 Automatic battery test system optional 12 V OPTIONAL E...

Page 4: ......

Page 5: ...ed service personnel The output may be energized when the unit is not connected to a mains supply Risk of electric shock hazardous live parts inside this unit are energized from the battery supply eve...

Page 6: ...atic battery testing optional High quality maintenance free lead acid type batteries High nonlinear load capacity special for computers Accessories o Optional UPS monitoring software T MON RUPS RUPSII...

Page 7: ...is an electronically controlled switching circuit checked by main controller board In case of inverter overload or any other faults STS transfers the critical load to the mains without any interruptio...

Page 8: ...Voltage Tolerance 1 Output Frequency 50 Hz Output Frequency Tolerance Line Synchronized 1 Free Running 0 2 Efficiency 100 Load 85 87 Crest Factor 3 1 Overload capacity 100 125 Load 2 5 min 125 150 Loa...

Page 9: ...Switch AC Input AC Output Output Fuse F4 External battery socket DB9 Port 2 3 kVA DB9 Port AC Output Main Switch PK1 On Off Switch UPS electrical connections 6 7 5 kVA 10 kVA Figure 2 2 Rear views DB...

Page 10: ...Selection The UPS is designed to be installed in a protected environment The following conditions should be prohibited 1 Blocking the airflow intake and outlet It is recommended to retain 10 cm 4 mini...

Page 11: ...d to the line voltage protected by a circuit breaker 1 Before connecting AC and DC power to the UPS make sure that the On Off Switch PK1 and Main Switch on the rear panel are in the 0 position OFF 2 C...

Page 12: ...ll sound intermittently Now the output receptacles are supplied from the battery source 4 Connect the power again and see that LINE FAILURE alarm is off 5 Now your UPS is ready to operate Plug in the...

Page 13: ...rotect your critical loads from loss of data or damage Battery back up time is more than 10 minutes for full load and can be extended by removing non critical loads After an utility power blackout the...

Page 14: ...button will change the status BATT USED It shows battery operation time the time passed after the last line failure alarm MOD ONLINE MOD ECONO This parameter determines the operation type of the UPS...

Page 15: ...out of tolerance ONLINE MODE UPS operating mode is ONLINE mode ECONO MODE optional This message shown the alternate operating mode is active OFFLINE 4 5 Automatic battery test system optional There ar...

Page 16: ...unicate so that the computer system is warned of impending UPS shutdown Software T MON RUPS RUPSII UPSILON 2000 and SNMP devices is available for most operating systems and is supplied with a signalin...

Page 17: ...ftware supplied with the module or it is possible to monitor the UPS through an Internet Browser It is possible to shutdown the servers or users with Client mate Software that communicates with SNMP m...

Page 18: ...system from several different locations at the same time 5 5 UPS Port Sharer Multiple server shut down unit Using one of this units you can automatic shut down of 4 8 servers or PC where without LAN...

Page 19: ...T 100 Series UPS User Manual 16...

Page 20: ...T 100 Series UPS User Manual 17 Connection Diagram Of The RMP COM1 T MON...

Page 21: ...iced only by authorized people In case of a persistent failure or problem properly turn off the unit first Then review the following check list Be prepared to answer the questions before calling the s...

Page 22: ...not apply if the product has been subjected to physical abuse improper installation unauthorized service or modification 2 The sole responsibility of corporation under this warranty shall be limited t...

Page 23: ...AGKK3772 02 2011...

Reviews: