Tescom NOBBY NTE11 User Manual Download Page 8

How to Use

1

Remove the cap.

2

Push the power switch and turn on the product.

3

4

Level Change 
Switch

Earth Plate

Do not use on areas other than below the 
eyes (from corner to corner).

There is a risk of accident or injury.

Do not use with contact lenses in.

There is a risk of eye problems.

Use for up to 7 minutes at a time, twice per day.
The power will turn OFF automatically 7 minutes after pushing the power switch.

There will be a beep and the LOW level display light will blink.
The roller ball will warm up to usable temperature approximately 2 minutes 
after pushing the power switch. The level display light will change from blink-
ing to a steady light.

● 

See Page 9 for using while plugged in.

Use  the  level  change  switch  to  set 
the microcurrent level.
It will be set at LOW upon turning on.

The display light for the level chosen will blink or 
be a steady light.

● 

When first using, start by using the LOW setting 

  for short periods of time.

● 

If something seems strange during use, stop 

  using the product.

Make sure that your hand is touching either the 
left or right earth plate when holding the main 
unit. While using, there is no effect if your hand 
is not touching the earth plate.

Hold  the  main  unit  so  your  hand  is 
touching the earth plate.

How to Use

5

 

Sometimes the head can become hot, so make 
sure to check the temperature of the head before 
placing it on your skin.

  

6

 

The power will turn off automatically after 7 minutes.

  

At that time, a beeping noise will alert you.

7

Always check with
 your fingertip.
(About 40°

C)

【When to Charge】

Beep

, bee

p

Long-term

 Storage

After use, push the power switch and turn off the power.
The level display light will turn off.

Perform maintenance (Page 9), put on the cap and store 
the product in an area free of dust and moisture.

Start using when the level display light 
becomes steady. Slowly move the roller 
ball from corner to corner of your eyes.

 Move slowly, without stopping in one spot.

 Do not use on areas other than those specified.

 If it feels too hot, stop using.

 Do not use continuously. Use only for less than 7 minutes at a time twice

 

 per day.

 

 More use can cause skin problems.

 Use in an ambient temperature between 10 and 40°

C.

 

 (Suggested ambient temperature: 15 to 35°

C)

Perform maintenance (Page 9) before storing.

1.

 Put the cap on the head.

2.

Make sure to charge it.

3.

Store in an area free of dust and moisture.

The signal for low batteries is when the battery 
light begins blinking while the power is on and a 
warning beeping occurs for 10 seconds before 
the power automatically turns off.

→ 

Charge immediately.

To continue using, use it while plugged in.

Alert

7

8

Summary of Contents for NOBBY NTE11

Page 1: ...n 21 23 24 25 30 30 28 29 26 27 29 29 Eye Care NTE11 4374 1 Table of Contents Manual NTE11 EyeCare Make sure that the roller ball is undamaged and not an abnormal temperature before use Inspecting Eye...

Page 2: ...here is a risk of the medical electron ics malfunctioning Consult with a doctor before use if any of the following apply Heart problems Acute painful illness Fever Abnormal blood pressure Infectious d...

Page 3: ...Do not let children use the product Do not use in reach of toddlers There is a risk of accident or injury Do not wrap the power cord around the power adapter There is a risk that the power cord will...

Page 4: ...t modify the product Do not dismantle or repair the product if you are not a repair technician There is a risk of fire electric shock or injury Do not drop or hit the product Do not apply strong impac...

Page 5: ...perform maintenance on the ball Page 9 Earth Plate Touch either the left or right one when using Nickel Metal Hydride Battery Internal Battery Light Normal Use Off While Charging On Charging Off Char...

Page 6: ...approx imately 4 uses 7 minutes each Based on factors such as conditions of use and maintenance the number of uses may decrease When the operating time after charging becomes extremely short the foll...

Page 7: ...risk of accident or injury Heart problems Acute painful illness Fever Abnormal blood pressure Infectious disease Tuberculosis Malignant tumor Facial neuralgia Pregnancy While on period Atopic eczema...

Page 8: ...erature approximately 2 minutes after pushing the power switch The level display light will change from blink ing to a steady light See Page 9 for using while plugged in Use the level change switch to...

Page 9: ...ady Slowly move the roller ball from corner to corner of your eyes Move slowly without stopping in one spot Do not use on areas other than those specified If it feels too hot stop using Do not use con...

Page 10: ...lock wise to fix it to the main unit Place the ball cover and roller ball on a towel on top of a desk and push the ball from the top to remove it While holding the ball cover in one hand push the ball...

Page 11: ...r power adapter is abnormally hot When charging or using while plugged in there is a shock when touching the main unit The safety device is not functioning properly The power cord is almost disconnect...

Page 12: ...11...

Page 13: ...12...

Page 14: ...13...

Page 15: ...14...

Page 16: ...15...

Page 17: ...16...

Page 18: ...17...

Page 19: ...18...

Page 20: ...19...

Page 21: ...20...

Page 22: ...21...

Page 23: ...100 240V 22...

Page 24: ...23...

Page 25: ...1 ON LOW OFF 29 10 24...

Page 26: ...1 2 OFF 5 1 5 4 1 7 1 10 2 10 40 1 25...

Page 27: ...1 2 1 7 7 26...

Page 28: ...1 2 3 4 1 7 1 2 7 OFF LOW 2 29 LOW LOW 27...

Page 29: ...5 6 7 7 40 29 1 2 1 7 10 40 15 35 29 10 28...

Page 30: ...100 240V 1 2 3 4 3 2 1 5 OFF 27 28 25 OFF 29...

Page 31: ...7 OFF NTE11 5 AC100 240V 50 60Hz 86g DC3 6V 750mAh 1 10W 135 34 33mm HI LOW 30...

Page 32: ...Eye Care NTE11 4374 1 N E Printed in Japan Tescom Denki Co Ltd...