![Tescom DS300SHPA Series User Manual Download Page 12](http://html1.mh-extra.com/html/tescom/ds300shpa-series/ds300shpa-series_user-manual_1090906012.webp)
10
1.4 Technical Specifications
MODEL
DS310SHPA DS315SHPA DS320SHPA DS330SHPA
Output (KVA)
10 kVA
15 kVA
20 kVA
30 kVA
Output (KW)
8 kW
12 kW
16 kW
24 kW
Output Power Factor
0,8
INPUT
Number of Phases
3 Neutral
Input Voltage
220/380, 230/400 or 240/415 Vac
Input Voltage Tolerance
+20% , -25% (+15% at 240/415Vac)
Input Power Factor (PF)
0,98 - 0,99 (at full load)
Input THDI
<= 4% (at full load)
Input Frequency
50/60 Hz.
±
10%
By-pass Voltage
220/380, 230/400 or 240/415 Vac 3 Phase + Neutral
By-pass Frequency
50/60 Hz.
RFI Level
EN62040-2
OUTPUT
Number of Phases
3 Neutral
Output Voltage
220/380, 230/400 or 240/415 Vac
Output Voltage Tolerance
±
1%
Output Frequency
50/60 Hz
Output Frequency Tolerance (Synchronous)
±
2%
Output Frequency Tolerance (Battery)
±
0,1% (free/battery operation mode)
Efficiency (100% Load)
up to 94%
Load Crest Factor
3:1
Output Voltage THD (linear load)
<=2%
Overload
125% Load 10min. , 150% Load 1min.
BATTERY
Total Number
60 blocks 12V (2x30 serial 60 batteries)
Float Charge Voltage (25
0
C)
±
405V DC
End of Discharge Voltage
±
300V DC
Battery Test
Automatic and Manual
Boost Charge
Available
COMMUNICATION INTERFACES
RS232 Com Port
1 each standard
External Temperature Measurement Input
Available (standard)
RS485 Comm. Port
Optional
Remote Monitoring Panel
Optional
SNMP Adapter
Optional
Modbus Adapter
Optional
Alarm Relay Contacts
3 each outputs (load on bypass, line failure, battery low)
2 each aux. outputs (function programmable)
Digital Inputs
1 each
Emergency Power-Off Input
Available (standard)
ENVIRONMENT
Operating Temperature
0 – 40
0
C
Operating Humidity
<= %90 (non-condensing)
Acoustic Noise
<55dB
<57dB
<61dB
Dimensions (WxDxH) (mm)
300 x 770 x 700
Device Type and Protection Class
Class 1 – IP20
Weight (Without Batteries) (app. kgs)
42
46
50
Summary of Contents for DS300SHPA Series
Page 1: ...DS300SHPA SERIES DSP Controlled UPS pf 0 8 10 15 20 30 kVA 3 Phase IN 3 Phase OUT USER MANUAL...
Page 2: ......
Page 17: ...15 Figure 2 3 External Battery Connections 60x12V 30x12V Batteries 30x12V Batteries...
Page 18: ...16 Figure 2 3a DS300SHPA Series 10 15 20 KVA Internal Battery Connections 60x12V 5Ah...
Page 19: ...17 Figure 2 3a DS300SHPA Series 10 15 20 KVA Internal Battery Connections 60x12V 7 9Ah...
Page 70: ......
Page 71: ...AGKK13761 10 2021...