(3). Stop recording : 

 

 
  (4). Reset datalogger : 

 

 

Note : If “

  REC
ERASE

” pressed while memory is full, “

” will display. 

 

7. MODE SETTING 

MAX

MIN

AVG

 

 

: Button for increasing the value of Parameters, increasing the 

parameter rapid.   

REL

J

 

      : Button for moving to the desired parameter. 

7-1 Date 

Time Setting : 

 Start with the power off mode.    Keep pressing 

T1 T2
T1-T2

  button, then 

press 

ON

HOLD

OFF

  button turn on, it will be enter setting mode. 

 

 Press 

C

F

 

(clock) button enter year. 

 Press 

MAX

MIN

AVG

  button for increasing the value of parameters, increasing the 

parameter rapid. 

 Press 

REL

J

  button for moving to the desired parameter. 

Set sequence : yyyy

MM

dd

hh

mm 

Then pls press 

C

F

  (clock) button to save the set value.    While in the set 

mode, if users intend to escape from the mode and don’t want to save the 

value, users can press 

ON

HOLD

OFF

  to end it. 

  Each data you recorded will be saved together with date and time. 

7-2 Set for Recording interval time 

 Start with the power off mode.    Keep pressing 

T1 T2
T1-T2

  button, then 

press 

ON

HOLD

OFF

  button turn on, it will be enter setting mode. 

 

 Press 

  REC
ERASE

  (INTV) button to set interval time. 

 Press 

MAX

MIN

AVG

  button for increasing the value of parameters, increasing the 

parameter rapid. 

 Press 

REL

J

  button to adjust the next parameter (second). 

 Press the 

  REC
ERASE

  button again to 

stop recording.

 

 Start with the power off mode. 

Keep  pressing 

  REC
ERASE

  button, 

then press 

ON

HOLD

OFF

 

 

button turn on, 

the LCD display “dEL”.

 

Summary of Contents for TES-1307

Page 1: ...y as specified in this manual otherwise the protection provided by the meter may be impaired Environment conditions Altitude up to 2000 meters Relatively humidity 80 max Operation Ambient 0 40 Safety symbols When servicing use only specified replacement parts Caution refer to this manual before using the meter Dangerous voltages Meter is protected throughout by double insulation or reinforced insu...

Page 2: ...mensions 145mm L x 68mm W x 35mm H 5 7 L x 2 7 W x 1 4 H inches Weight Approx 235g with battery Accessories Instruction manual carry case battery CD Software RS 232 cable 9 pin to 25 pin gender changer 2 2 2 Electrical Specifications Basic Accuracy 23 5 Calibration Accuracy are of reading degree at 18 to 28 with relative humidity up to 80 For single thermocouple measurements Function Resolution Ra...

Page 3: ...at had been recorded since the meter last reset c Press the button again the LCD will show M AVG The average of the first 10 records d Press the button again the LCD will show M The LCD display will be back the original status e Press and hold the button for 3 seconds the recorded maximum and minimum values will be cleared The meter will be back to the normal mode Note When MAX MIN AVG mode is sel...

Page 4: ...ION INSTRUCTIONS 1 Plug the temperature probe into T1 or T2 input connectors 2 Press ON HOLD OFF button once to power on the meter The left bottom side of LCD will show the date and time and then time counting status 3 If appears it indicates no temperature probe or the probe is broken 4 Input the thermocouple to measure T1 T2 and LCD will display the value of T1 T2 simultaneously If users want to...

Page 5: ...yyy MM dd hh mm Then pls press C F clock button to save the set value While in the set mode if users intend to escape from the mode and don t want to save the value users can press ON HOLD OFF to end it Each data you recorded will be saved together with date and time 7 2 Set for Recording interval time Start with the power off mode Keep pressing T1 T2 T1 T2 button then press ON HOLD OFF button tur...

Page 6: ...connect battery from instrument and replace with a standard 9 Volt battery and replace bottom cover 9 OPTIONAL ACCESSORY K CA type thermocouple Model Range Tolerances Description TP K01 Bead probe 50 to 200 58 to 392 2 2 or 0 75 3 6 or 0 75 with Teflon tape insulation Maximum insulating temperature 260 TP K02 immersion probe 50 to 1000 58 to 1832 2 2 or 0 75 3 6 or 0 75 3 2φ 150 metal sheath 100 C...

Page 7: ...nstruction of RS 232 interface software operation and relevant information RS 232 protocol are enclosed within the content of CD ROM please open the CD ROM for details 12 TES ELECTRICAL ELECTRONIC CORP 7F No 31 Lane 513 Rui Guang Road Neihu Dist Taipei Taiwan R O C Tel 02 2799 3660 Fax 886 2 2799 5099 E Mail tes ms9 hinet net http www tes com tw Jan 2007 5 ...

Reviews: