![Teryair DP 25 ALS Operation And Maintenance Manual Download Page 8](http://html1.mh-extra.com/html/teryair/dp-25-als/dp-25-als_operation-and-maintenance-manual_1090482008.webp)
FF-MM-326-REV -01
Page 8
Operation and Maintenance Guide SDP 25 Metal Series
Maintenance
Regular inspection and maintenance schedules will greatly enhance the life of the pump and
will ensure a trouble free and safe working environment with little chance of breakdowns.
Follow the instructions clearly in “Disassembly and Reassembly”of the pump and in the
troubleshooting section.
Use genuine Teryair spares and if possible mention the serial number of the pump when
ordering spares.
Always replace elastomers as a set, eg diaphragms, balls and seats.
Disassembly and Re assembly
• Shut off air supply and allow residual Pres-
sure to bleed off.
• Disconnect air supply
• Disconnect suction and discharge piping
• Turn pump upside down allow process fluid
to drain away. If fluid is hazardous due care
should be taken.
• Make a mark to indicate the positioning of
each liquid chamber relative to the housing.
NOTE: Replace worn parts with genuine
TERYAIR parts for reliable performance.
1. Replacement Of Diaphragms, Ball
& Ball Seat.
a. Unscrew the four manifold bolts (19) & nuts
(18). Remove the top and bottom manifolds
(3 & 2).
b. Inspect manifolds (2 & 3), O-Ring (14), and
valve balls (13). If swelling, cracking or
other damage is apparent, these parts must
be replaced with genuine TERYAIR parts
Note: For SS Models inspect Ball Seal (14),
Ball Seat (14A), Ball cage (14B) & Ball (13).
If swelling, cracking or other damage is
apparent, these parts must be replaced with
genuine TERYAIR parts.
c. Now unscrew hex socket head bolt (21)
& nut (20) of any one side and proceed to
remove the big clamp (7). Now remove the
outer chamber (4). Now repeat the same
procedure to remove the second outer
chamber.