background image

4 VM  SG Iron and Stainless Steel Construction, All variants

Models

Descriptions

4VMSXXX

FOOT

 Model with Lube / Lube-Free, SG Iron / SS & NPT / BSPT  

Variants

4VMLXXX

FACE

 Model with Lube / Lube-Free, SG Iron / SS & NPT / BSPT   

Variants

4VMNXXX

NEMA

 Model with Lube / Lube-Free, SG Iron / SS & NPT / BSPT   

Variants

4VMDXXX

IEC

 Model with Lube / Lube-Free, SG Iron / SS & NPT / BSPT   

 Variants

4 V M

Read this manual carefully before installing, operating or servicing this equipment. It’s the responsi-

bility of the employer to ensure this manual is read by the operator. Please preserve this manual.

This document is issued with Product Serial No

Operation and Maintenance Guide

Summary of Contents for 4 VM Series

Page 1: ...VMNXXX NEMA Model with Lube Lube Free SG Iron SS NPT BSPT Variants 4VMDXXX IEC Model with Lube Lube Free SG Iron SS NPT BSPT Variants 4 V M Read this manual carefully before installing operating or se...

Page 2: ...cal Data Safety Instructions Installation Instructions Operating instructions Suggested Lubricants Troubleshooting Dis assembly and Re assembly Exploded View for 4VM Air Motor Bill of Materials for 4V...

Page 3: ...35 lbs in Air Consumption 0 to 120 m3 hr 0 to 72 cfm Motor Weight 3 8 kgs 8 3 lbs Operating Pressure 1 4 to 7kg cm2 20 to 100PSI Max Allowable speed 3500 rpm ATEX limit 500 2500 2000 1000 1500 3500 3...

Page 4: ...um surface temperature listed on the motor is for nor mal environmental and installation conditions Fort air motors Temp Class T6 Gas and T85 C Dust The maximum surface temperature Ex code ll 2 G Ex h...

Page 5: ...If your measured temperature does ex ceed listed value consult with your Distributor Representative for a recommendation Installation Instructions An automatic air line lubricator should be in stalle...

Page 6: ...e Check the direction of the motor airflow A single rotation motor will operate properly only in one direction Single rotation motors require a muffler to be connected to the air port Remove the plast...

Page 7: ...or serviced Air source inadequate Inspect and repair Air source too far from motor Reconfigure setup Suggested Lubricants Brand Above 27 Deg C From 5 Deg C to 27 Deg C Below 5 Deg C Shell Toona R 72 T...

Page 8: ...ssion Spring 17 from Rotor Shaft 4 and replace them with new ones if found damaged e From front side of motor remove Internal Circlip 20 using circlip plier from Front flange 2 then remove Oil Seal 9...

Page 9: ...369 REV 02 Page 9 Operation and Maintenance Guide 4 VM Air Motor Series Exploded View for 4VM Air Motor 1 3 4 5 6 8 10 11 12 14 15 19 2 9 15 19 6 20 21 22 13 18 17 16 FACE FOOT 20 15 9 7 19 2 IEC NEM...

Page 10: ...04 21 02 1 1 1 1 1 1 1 1 6 BEARING 2Z ZZ 804 50 01 2 2 2 2 1 1 1 1 7 BALL BRG 2Z ZZ 803 50 01 1 1 1 1 8 O RING 804 40 01 1 1 1 1 1 1 1 1 9 OIL SEAL 804 60 01 1 1 1 1 9 OIL SEAL 804 60 02 1 1 1 1 10 SH...

Page 11: ...7 04 1 1 1 1 1 1 1 1 6 BEARING 2Z ZZ 804 50 01 2 2 2 2 1 1 1 1 7 BALL BRG 2Z ZZ 803 50 01 1 1 1 1 8 O RING 804 40 01 1 1 1 1 1 1 1 1 9 OIL SEAL 804 60 03 1 1 1 1 9 OIL SEAL 803 60 02 1 1 1 1 10 SHIM 8...

Page 12: ...FF MM 369 REV 02 Page 12 Operation and Maintenance Guide 4 VM Air Motor Series Foot Mounting 4VM FACE Mounting 4VM Dimensional Data...

Page 13: ...FF MM 369 REV 02 Page 13 Operation and Maintenance Guide 4 VM Air Motor Series NEMA Flange Mounting 4VM IEC Flange Mounting 4VM...

Page 14: ...uide 4 VM Air Motor Series Repair KIT Ordering No Suitable for 8049701 Suitable for 4 FACE FOOT VM variant 8049702 Suitable for 4 VM IEC NEMA variant Repair Kits for 4VM Note Repair Kit includes Blade...

Page 15: ...EN ISO 80079 36 2016 Explosive atmospheres Part 36 Non electrical equipment for explosive atmospheres Basic method and requirements EN ISO 80079 37 2016 Explosive atmospheres Part 37 Non electrical e...

Page 16: ...after deposit with the transporter for shipment iii a Product is not properly preserved packaged stored processed or handled after receipt iv a Product is not used and maintained in accordance with T...

Page 17: ...FF MM 369 REV 02 Page 17 Operation and Maintenance Guide 4 VM Air Motor Series This page is intentionally Left blank...

Reviews: