background image

Lifestyle Elecs & Fault Finding - XH00219 

Issue:  C 

Page 9 of 14 

 

 

Fault Finding 

 

Before undertaking any detailed Fault Finding, confirm that the basic fault finding in the user 

instructions has been undertaken. 
 

Notes on fault finding 

 

1)  Before commencing fault finding using the flow chart:- 

 

a) 

Check the status of all LED’s and fuses – and take any necessary action 

 

b) 

Check door is closed 

 

c) 

Ideally the lift should be in mid position i.e. off its limit switches 

 

d) 

Note that LED’s on the sling board are only illuminated during the “Light on” period 

(initiated by up/down/door signal) and when the user LED panel is disconnected. 

 

 

2)  Voltage checks indicate 13.6V this will vary according to battery condition and where it is 

being measured – but under no load conditions should never be below 11.5V 

 

3)  If the alarm sounds when lift ascending the float switch is closed – detecting a full fluid 

catch tank. 

Phone Support Fault Finding 

 

User Display LED's. 

 

Note: key fob to enable the lift is optional. 

 

Up Underpan obstruction       –   Green out. 

 

Underpan Down obstruction  –   Yellow Out. 

 

Trapdoor Up/Down obstruction; Door Lock Error; Proving Switch Error  –  Blue, Green & 

Yellow Out. 

 

Note: Top Limit red plunger sticking down will cause the Green LED’s to extinguish. 

 

 

THE PRIMARY EMERGENCY LOWERING PROCESS WILL OPERATE WHEN THE 

SPRUNG EMERGENCY DUMP SWITCH ON THE CARRIAGE CONTROL STATION IS 

TURNED AND HELD IN THE CLOCKWISE DIRECT AND THE DOWN SWITCH IS 

SIMULTANEOUSLY PRESSED. THE LIFT WILL SAFELY TRAVEL DOWNWARDS. 

 

 

BACK-UP EXTERNAL EMERGENCY LOWERING ON A TERRY LIFESTYLE LIFT IS 

ONLY TO BE CARRIED OUT IF SOMEONE IS TRAPPED INSIDE THE LIFT –  not as a 

means of down operation until an engineer can attend.

 

Summary of Contents for Lifestyle 4.3

Page 1: ......

Page 2: ...Cap Connections 5 Wiring Diagram 3 Trailing Cable Connectors 5 Wiring Diagram4 Sling Main Wiring 7 Fault Finding 9 Phone Support Fault Finding 9 Terry Lifestyle Fault Finding Emergency Circuit 10 Take...

Page 3: ...cy Dump Relay is controlled directly from the Emergency Dump Enable Switch in the carriage along with the Down call button The mains intrusion for the Pump and Motor Unit can be found here Wiring Diag...

Page 4: ...Lifestyle Elecs Fault Finding XH00219 Issue C Page 4 of 14 Wiring Diagram 1 Lifestyle Lift Wiring to P Pack Circ Board CE966 XH00203F...

Page 5: ...Lifestyle Elecs Fault Finding XH00219 Issue C Page 5 of 14 Wiring Diagram 2 Top Cap Connections...

Page 6: ...Lifestyle Elecs Fault Finding XH00219 Issue C Page 6 of 14 Wiring Diagram 3 Trailing Cable Connectors CE2123 Sling PCB...

Page 7: ...Lifestyle Elecs Fault Finding XH00219 Issue C Page 7 of 14 Wiring Diagram4 Sling Main Wiring...

Page 8: ...Lifestyle Elecs Fault Finding XH00219 Issue C Page 8 of 14...

Page 9: ...der no load conditions should never be below 11 5V 3 If the alarm sounds when lift ascending the float switch is closed detecting a full fluid catch tank Phone Support Fault Finding User Display LED s...

Page 10: ...ery Negative C CE966 Powerpack PCB CB2 Resettable Fuse D CE966 Powerpack PCB TB4 STOP LINK E CE966 Powerpack PCB TB3 Pressure Switch Fitted on Ram 1 CE2123 Sling PCB TB6 EMERGENCY Trailing Cable 2 3 C...

Page 11: ...s D3 CE2123 Sling PCB TB11 Final Down Blacks D5 CE2123 Sling PCB TB11 Final Down Blacks D6 CE2123 Sling PCB TB11 Down Hold Trailing Cable Yellow D8 CE966 Powerpack PCB TB5 Trailing Cable Yellow DN Sig...

Page 12: ...U6 CE2123 Sling PCB TB8 Up Hold Trailing Cable Brown U5 CE2123 Sling PCB TB15 Underpan Up Separation O ride Brown U7 CE966 Powerpack PCB TB5 Up Hold Trailing Cable Brown Up Signal Final Relays Motor...

Page 13: ...Lifestyle Elecs Fault Finding XH00219 Issue C Page 13 of 14...

Page 14: ...Lifestyle Elecs Fault Finding XH00219 Issue C Page 14 of 14 XH00219C...

Reviews: