background image

This Steplift 1000 has been supplied by:

10199b

Summary of Contents for TSL1000

Page 1: ...TSL1000 Platform Lift Original instructions...

Page 2: ......

Page 3: ...s and Don ts 6 Controls 7 Operating the Lift 8 Emergency procedures 9 Emergency gate lock override 10 Maintenance Servicing 10 Fault finding 11 Safety feature checks 12 Service history record 13 Decl...

Page 4: ...duct gives you many years of reliable service Peter Morrey Managing Director DESCRIPTION The Terry TSL1000 Lift is designed to transport a single person in a wheelchair between two floor levels up to...

Page 5: ...f use of the lift is required this should be discussed with the manufacturer supplier as certain alterations may be needed Examples of changes of use are a change of type size and or weight of wheelch...

Page 6: ...lift is kept clear from debris e g litter and leaves Do not exceed the maximum lifting capacity of 39 stone 250 kg Always treat your lift with respect that should be shown to electrical and mechanica...

Page 7: ...of the hold to run type Maintain pressure on the switch until the lift reaches the upper or lower level To travel in the opposite direction release the switch wait 2 seconds and press again A master s...

Page 8: ...se for up to 10 seconds when the lift reaches the upper level Alternatively pressing the gate open button on the platform or on the upper call station will also release the gate Note that the lift can...

Page 9: ...he chord located beneath Please Note If the platform is at the upper level and will not lower it will be necessary to first remove the fuse as per emergency procedure a before following emergency proc...

Page 10: ...and repair of the product If a lifting platform is to be installed in an adverse environment the specifier and supplier shall determine the measures needed to ensure that safe operations are achieved...

Page 11: ...activated Ensure charger isolation switch is on Activate remote control enabler with key fob Lift rises short distance then stops Obstruction on ramp Remove obstruction on ramp Upper level Lift will n...

Page 12: ...the help of another person Folding ramp upper safe edge With the lift at lower level obstruct the upper surface of the ramp and send the lift up the lift should stop within 300mm of travel Upper leve...

Page 13: ...SERVICE HISTORY RECORD An entry should be added to the following table every time the lift is serviced Date Engineer Company Comments 13...

Page 14: ...2008 Electromagnetic Compatibility Product family standard for lifts escalators and moving walks Immunity BS6440 2011 Powered lifting platforms for use by disabled persons Person authorised to compile...

Page 15: ...cture Maximum load 250Kg 39 stone Maximum travel 1 metres Power supply 240V AC 50 60 Hz Control voltage 24V DC Hydraulic pump power consumption 600W maximum Hydraulic oil grade T22 Standards Designed...

Page 16: ...This Steplift 1000 has been supplied by 10199b...