Lift Malfunction
Fault
Indication
Cause
Remedy
No lift function at all.
No red LED on
powerpack cover.
No mains power to
the lift.
Check mains is on
and reset RCD/Spur
if required.
Lift will not travel in either
direction.
No lights on car
panel.
Door not shut or
remote fob off.
Press door button
Press button on fob.
Flat batteries in
smoke alarms.
Replace smoke
alarm batteries.
Lift will not go up.
One green off on
car panel.
Car safe edge
obstruction.
Remove obstruction
or free safe edge.
Both greens off on
car panel.
Infill panel obstructed
on upper surface.
Remove obstruction
from upper surface.
Lift will not go down.
One yellow off on
car panel.
Car underpan
obstruction.
Remove obstruction
from beneath
surface.
Both yellow off on
car panel.
Infill panel obstructed
on lower surface.
Remove obstruction
from lower surface.
Powered door will not
close fully.
Can be moved
easily by hand.
Door has disengaged
from drive
mechanism.
See pg 13 & 14
Person B emergency
unlocking.
Smoke Alarm Malfunction
Indication
Cause
Remedy
Alarm beeps twice every 45 seconds.
Unit Malfunction.
Call an engineer.
Alarm does not sound upon pressing test
button.
Unit Malfunction.
Call an engineer.
The operating light remains steadily on or off
(ie. Does not flash approximately once every 45
seconds when unit not in alarm).
Unit Malfunction.
Call an engineer.
Low Battery Warning
Indication
Cause
Remedy
Single short beep on lift car every 2 minutes.
Low Handset battery.
Replace CR2450
batteries in handset.
Double short beep on lift car every 2 minutes.
Low smoke alarm
battery.
Replace AA batteries
in smoke alarm.
Double long beep on lift car every 2 minutes.
Smoke alarm battery
dangerously low.
Replace AA batteries
in smoke alarm.
Lift will not travel in either direction.
Smoke alarm
batteries flat.
Replace AA batteries
in smoke alarm.