5 Appendix
5.1 Select 1 potentiometer calibration
If the valid positions of the Select 1 parameters (a value is recognized as valid when the
Select 1 LED is not flashing) do not correspond to the control knob increments on the
front panel of the Warp 9 (after a control knob has been replaced, for example) you may
set and permanently store the positions recognized as valid. Proceed as follows:
n
n
n
n
n
n
n
When switching the device on, press and hold the Program and Write buttons at the
same time. The Select and Trigger LEDs must remain lit. The LP, HP and BP LEDs
are not lit.
The various valid control knob positions can be calibrated without the left and right
values. When calibrating, set all 5 control knobs to one of 7 possible positions. These
7 possible positions are shown below using the LFO Reset control as an example.
Turn all 5 control knobs below Modulation 1 to position 1. All controls should be
positioned so that they point exactly at the second value (LFO Reset knob on C4, LFO
Wave on Sawtooth, ENV Mode on N2). The Trigger Source and VCA Mode controls
should also be in these positions, even though they do not have values at this point,
Save this position by pressing the Write button.
To set the next position (2), press the Program button briefly. The LP, HP and BP
LEDs will now light as shown below under Position 2. Next, set all 5 controls in Posi-
tion 2 so that they point exactly at the third value (LFO Reset: C8, LFO Wave: , ENV
mode: N3). The ENV Mode and VCA Mode controls should also be in this position.
Save this position by pressing the Write button.
Repeat this process for the remaining positions 3 to 7, i.e. press the Program button
first to select the next position in accordance with the LEDs, set all knobs to the posi-
tion and save the control positions with the Write button.
n
n
After saving Position 7, press the Channel button to exit the calibration mode.
To check whether the calibration has been performed correctly, choose Select 1 and
set the controls to the position of the various values. The Select LED must remain lit
(value recognized). The value is invalid if the LED flashes between two values.
32
SINE WARP 9 (English)