2
Installation
When outputs of UP413 are working in parallel it is recommended to connect PS units to different lines of the mains or
one to the line directly, another via uninterruptable power source (UPS). Disconnected from the mains one PSU does not
disturb parallel working PSU.
Warning
!
• Maximal output current of parallel connected PS units can not exeed output current of one PSU.
• Connecting or disconnecting powering of modules must be done when PSU is disconnected from the mains.
• Connection of other model of PSU in parallel with UP413 is not allowed.
Perpendicular to the wall
Parallel to the wall
Figure 2. Mounting of PSU
Technical characteristics
Supply voltage limit values
187-250 V~ 50/60 Hz
Output voltage
12 V ± 0.5 V
Power consumption
65 W max.
Output current
0-4.5 A short circuit and overload protected
Ripple, 100 Hz
< 10 mVpp
Noise
< 50 mVpp
Temperature range
0…50°C
Dimensions/Weight (packed)
198x107.5x36 mm/0.97 kg
MOUNTING
The module
or mounting bracket must be fixed with steel screws
Ø 3.5-4 mm. The screws are not included in a package.
Mounting on a wall by screws
Mounting on a bracket (supplied)