Power supply for parallel connection UP413
Vers. 1.03
1
EN
Product description
Switch mode power supply unit (PSU) UP413 is intended to supply devices, required increased reliability of supply voltage
for back-up function implementation. Enable work of 2 or more PSU UP413 in parallel connection.
The unit is intended for indoor use only.
Safety instructions
Installation of system must be done according IEC60728-11 and national safety standards.
The PSU is powered from the mains 230 V~. This voltage is dangerous to life.
Any repairs must be done by a qualified personnel.
PSU is double isolated from the mains 230 V~.
Do not remove the cover without disconnecting PSU from the mains.
Do not plug the PSU into the mains supply if the power cord or plug is damaged.
To disconnect the PSU from the mains completely, disconnect plug from the mains socket.
The mains socket must be easily accessible.
PSU shall not be exposed to dripping or splashing water and no objects filled with liquids, such as vases, shall be placed
on it.
Avoid placing PSU next to central heating components and in areas of high humidity.
No naked flame sources, such as lighted candles, should be placed on PSU.
If the PSU has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before plugging
into the mains.
The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers,
table-cloths, curtains.
Mount the PSU in vertical position.
From top, front and bottom of installed PSU must be at least 10 cm free space.
External view
Figure 1. External view of PSU UP413
1
- mains connector
2
-
STATUS
- indicator of the module's status (at normal conditions glows green,
at overload or overtemperature glows red)
3
- power distribution bus connectors
4
- 12 V output (screw terminal)
5
- functional grounding clamp
1
3
230V~
50/60 Hz
65Wmax
UP413
STATUS
TERRA
230V~
50/60 Hz
65Wmax
12V 4.5Amax
2
12V 4.5Amax
4
5