3. External view
Figure 1. External view of the transmodulator
DC IN 12V
--
++
tdx440
RESET
ETHERNET
TERRA
3
4
2
5
6
7
tdx440
DC IN 12V
--
++
8
9
1
IN 1
IN 2
THRU 1
THRU 2
IN 1
IN 2
THRU 1
THRU 2
1
-
IN 1, IN 2
- RF input of SAT IF signal, DC output for LNB. F sockets.
THRU 1, THRU 2
- RF output (input signal loop-through). F sockets.
2
-
ETHERNET
- control Ethernet interface. RJ45 socket.
3
- ACTIVITY (yellow) indicator of the control Ethernet interface.
4
- LINK (green) indicator of the control Ethernet interface
5
-
RESET
and default IP button.
Press button for more than three seconds to set default IP address of the control Ethernet interface. Ethernet
led indicators "activity" [3] and "link" [4] will start to toggle to inform, that the reset IP address request has been
accepted. Device will be restarted with default IP address.
To restore all parameters to default values (including password), keep pressing the button for additional 4 seconds.
The green (link) indicator will start blinking after that time indicating, that a “restore defaults” command has been
accepted. Now the button can be released. Yellow (activity) indicator will light on while resetting parameters. After
that device will restart with all default values
6
- RF input (output signal loop-through). F socket.
7
- RF output. F socket.
8
- Power distribution bus connector.
9
- +12 V DC powering input. Screw terminal.