IMPORTANT WARNINGS! 

Before connecting any products to a system, it is essential to make sure the 

system power supply is switched off

. Avoid 

short-circuit or overload of any power supply. Never “HOT-SWAP” any system components as this may result in damage to 

the newly introduced or existing components.

  The SRM564, SRM584 and SRM564T, SRM584T multiswitches are intended only for indoor installation or installation 

in a suitable weatherproof outdoor cabinet. These multiswitches must not come into contact with moisture or be installed in 
areas of high humidity or heat. 

 Multiswitches are suitable for moderate and tropical climates.
 Always mount the multiswitches securely to a wall or bulkhead panel so it cannot hang or swing on its coaxial cables as 

this may strain the internal circuit board and components.

 Always connect all of the coaxial cables to the multiswitches before connecting the power. These units are not designed 

to be “HOT-SWAPPED” or connected to a live system.

 Always be sure that connecting cables shield and multiswitches functional grounding clamp have common potential 

before powering the system. Floating voltages can be created in an un-earthed system which may cause damage and can 
be dangerous.

 Momentary short-circuit of any cables may be enough to damage the sensitive electronics within the multiswitch or the 

connected system.

 Always allow plenty of ventilation around the multiswitch and do not allow it to be covered with materials such as loft 

insulation.

 We recommend at least 5 cm of airspace around the multiswitch. Digital products can get hot to the touch and require a 

flow of air to avoid overheating.

  LNBs and other system equipment connected to the multiswitch SAT trunks inputs/outputs can be powered from the 

same power supply as the multiswitch (see chapter „Installation instructions”).

To avoid damage not covered by warranty 

DO NOT EXCEED MAX. CURRENTS

. See “

Technical 

characteristics

” for max. current for external equipment.

DO NOT OPERATE THE DC POWER TO H or V TRUNK LINES SWITCHES

 (see Figure 1, pos. 21, 23) 

unless you totally understand the power demands of the system and confirmed they are 3.2 A total or less 

per H or V lines. 

ALWAYS LEAVE THE DC POWER TO H or V TRUNK LINES SWITCHES IN THE “OFF” 

POSITION

 when inserting the SRM564, SRM584 and SRM564T, SRM584T into an existing multiswitches 

installation.    
Damage caused by current overload is not covered by the manufacturer’s warranty.

2

Summary of Contents for SRM564

Page 1: ...ontrol for SAT IF and DTT SRM564 SRM584 signals negating the need for any gain or level adjustments in most installations Multiswitch is built into a zinc alloy die cast housing for extreme interference immunity The housing of multiswitches meets more stringent screening requirements according to EN50083 2 class A Control according to EN50494 EN50607 SCR dSCR commands as well as Legacy 13 V 18 V 2...

Page 2: ...stem Floating voltages can be created in an un earthed system which may cause damage and can be dangerous Momentary short circuit of any cables may be enough to damage the sensitive electronics within the multiswitch or the connected system Always allow plenty of ventilation around the multiswitch and do not allow it to be covered with materials such as loft insulation We recommend at least 5 cm o...

Page 3: ...o V H Voltage in trunk Power via DC IN Legacy dSCR DTT DiSEqC control DC to from H lines DC to from V lines Low voltage in trunk 27 22 23 19 24 25 26 Manual 13 14 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 20 11 12 15 16 17 18 21 DC IN H DC IN V 20V 2A H H V 20V 2A V DTT DTT Frequency SAT TV range DTT Trunk loss SAT TV DTT Current consumption 20 V 950 mA max 290 2350 MHz 47 862 MHz 4 dB 4 dB dSCR multiswitch ...

Page 4: ...SCR output1 pair A UB DTT 16 dSCR output2 pair A UB DTT 17 dSCR output1 pair B UB DTT 18 dSCR output2 pair B UB DTT 19 Wideband Quattro switch 20 DC IN H 20 V power input switchable to H lines by switch pos 21 see Installation instructions 21 DC power to from H trunk lines switch see Installation instructions 22 DC IN V 20 V power input switchable to V lines by switch pos 23 see Installation instr...

Page 5: ...Diagram of DC paths Figure 3 Diagram of DC paths 5 DC IN H DC IN V 20V 2A 20V 2A DTT H H V SAT A SAT B On Off On Off V DC to from H lines DC to from V lines DiSEqC control DC DC converter ...

Page 6: ...N OFF WARNING Don t exceed the current capability of system power supply and H trunk lines See Technical characteristics SERIOUS DAMAGE CAN OCCUR IF OVERLOADED 4 Multiswich is powered from lo cal PSU 20 V via DC IN V input see Figure 1 pos 23 Recommended for use is PS202F PSU V trunk lines are DC isolated from it OFF OFF WARNING BEFORE CONNECTION ALWAYS CHECK DC TO FROM H V TRUNK LINES SWITCHES se...

Page 7: ...ered from DC IN H port Attention increased current consumption Low voltage in H line Multiswitch powered from H line Voltage in H line from another system power point Attention increased current consumption Yellow blank 15 20V 0V OFF OFF 0V 0V Normal operation Multiswitch powered from DC IN V port Green blank 0V 0V ON OFF 15 20V 0V Normal operation Multiswitch powered from V line Blinking Yellow G...

Page 8: ...DiSEqC command according EN50494 EN50607 Output User Bands UB are the same in all subscriber outputs see Table 3 3 PIN Codes see Table 3 and see chapter Configuration 4 Only one UB plan is set depended of delivery region if you need another plan see chapter Configuration or contact TERRA UAB 5 DC power to H V trunk lines switches set see Figure 1 pos 21 23 in position OFF Table 3 Marking v 0 Marki...

Page 9: ...tal 96 UB SRM584 SRM584T total 128 UB for use with STBs supporting DiSEqC commands according to standard EN50607 dSCR 2 Default settings Dynamic mode can be changed to Static mode 3 Default setting Satellite A B can be changed to C D see Application diagrams for installation 4 wideband LNBs SAT B C D in the case Quattro LNB IF range input mode PC Windows software can be free downloaded from www te...

Page 10: ... MHz adjustable dSCR mode dSCR mode output level 84 dBµV adjustable AGC controlled legacy mode output level 78 dBµV AGC controlled typical DTT output level 82 dBµV max 8 DTT channels AGC controlled adjustable DTT loss 18 dB Decoupling SAT IF inputs SAT IF inputs 30 dB SAT IF inputs tap outputs 30 dB SAT IF Terr TV 25 dB DC pass through SAT IF 3 2 A max 1 6 A max through one line trunk lines DTT 20...

Reviews: