Electrical connection for all brine and groundwater heat pumps of the type TERRA
Page 13
1 2 3 4 5 6 7
12 13 14
21 22 23
28 29 30
Main
electricity
con-
nection
230
V
/50
Hz
N Pe
N Pe
brine
resp.
deep
well
pump
230V
Control
c
urrent
con
-
nection
230V/50Hz
N Pe
L
L
L
Pe
water
pressure
switch
(accessory)
Subsequent the necessary connections that are per-
formed as inline connections are shown. The gray
connections have to be connected on site, whereby
the rest is pre connected already.
The wire diameter for the main electricity and for the
brine resp. the deep well pump wire has to be dimen-
sioned corresponding to the technical data. (See pa-
ge 3 and 4 for brine resp. groundwater systems)
24 25 26
Pe
External
activation
EW
contact
31
A
C
B
P<
Connecter description:
Main electricity connecter 230V 50Hz
:
1. Compressor 230V, pre connected
Connection
connection 230V/50H
(if no control is integrated): a po-
tential free contact has to be connected between con-
necter 24 and 25
a potential free contact has to be connec-
ted between connecter 25 and 26 (remove the pre in-
stalled bridge)
Connectern 1 to 3:
Connecter 4 to 7:
Connecter 8 to 11:
Connecter 21 to 23:
Connecter 24 and 25:
Connecter 25 and 27:
brine resp. deep well pump
Control current
z
External activation
EW barrier:
2. Compressor 230V, pre connected
Connecter 12 to 14:
27
Connecter 28 to 31:
Water pressure switch, at groundwater systems to
be installed on site, whereby the pre installed bridge
has to be removed; at brine systems the contact 28
and 30 has to be bridged.
1.
Compressor
230V
,
pre
installed
8 9 10 11
2.
Compressor
230V
,
pre
installed