External view of amplifier PA321TP

1

 

-

 IN 1 / DC out

 -

 

VHF / UHF input 1, 

DC output. F type.

 

2

 

-

 IN 2

 -

 

VHF / UHF input 2. F type.

3

 

-

 FM

 -

 

FM input. F type.

4

 

-

 RF OUT / DC IN

 - RF signal output connector (combined DTT and FM inputs) / DC IN

.

 F type.

5

 

-

 TEST -30 dB

 - RF output signal test point

.

 F type.

6

 

-

 DC IN 12 V

 - DC entry 3.5/1.3 mm. DC jack.

7

 

-

 Control

 - programming input. 

8

 

-

 Adjust

 - adjust LED (

green

9

 

-

 Error

 - error LED (

red

10

 

-

 

functional ground clamp

11

 

-

 

mounting supports

Figure 2. External view of the amplifier PA321TP

The power supply unit 12 V DC SYS1381N-1212-W2E

3.5 mm/1.3 mm DC jack;
The power supply is supplied with the amplifier.

3

Requirements for external power supply unit (PSU)

• Output voltage 

12 V

• Output current 

recommended to use

                                                       PSU with 50% extra power reserve
• Ripple at single and/or 

< 10 mV p-p

  double mains frequency
• Ripple & noise  

< 200 mV p-p

• Short circuit protection
• Double insulated (marked 

 )

• Meet EN 55022 class B conducted emissions requirements, 

  measuring with grounded load

Installation and configuration instructions

Read the safety instruction first. 

Fit amplifier on mounting place and connect all necessary RF cables, connect 75 Ω loads to the unused F sockets, 

power on amplifier. Adjust (

green

) and Error (

red

) LED’s blinking simultaneously briefly.  Adjust LED light up after that.

All configurations will be made with TERRnet App (see TERRnet App).

Connect Windows PC or Android smartphone to the amplifier

.

Select the necessary country (channels chart). 

Select the necessary channels, output level, equalizer, FM gain and send it to the device. 

Input channels numbers can’t be the same in different inputs. 

Don’t select empty channels.

Reduce output level if use more than 6 MUX (see Technical characteristics). 

Keep FM max output level 10 dB less than DTT signals. 

During the parameters sending Adjust LED blinking (

green

). Error LED blinking (

red

) if the input level is too low or too 

high for at least one selected channel.

7

1

2

3

4 5

6

8 9

10

11

11

Summary of Contents for PA420T

Page 1: ...ge is dangerous to life The amplifier PA420T is double isolated from the mains 230 V The amplifier PA321TP is powered from the external stabilized power supply 12 V DC This voltage is not dangerous to life Any repairs must be done by skilled personnel Do not remove the cover of the power supply section without disconnecting the unit from the mains supply Do not plug the amplifier into the mains su...

Page 2: ...t F type 5 RF OUT RF signal output connector combined DTT and FM inputs F type 6 TEST 30 dB RF output signal test point F type 7 Control programming port 8 Adjust adjust LED green 9 Error error LED red 10 power cord 11 functional ground clamp 12 mounting supports Figure 1 External view of the amplifier PA420T 1 3 2 5 4 6 7 8 9 10 11 12 position of control port 7 12 ...

Page 3: ...ted marked Meet EN 55022 class B conducted emissions requirements measuring with grounded load Installation and configuration instructions Read the safety instruction first Fit amplifier on mounting place and connect all necessary RF cables connect 75 Ω loads to the unused F sockets power on amplifier Adjust green and Error red LED s blinking simultaneously briefly Adjust LED light up after that A...

Page 4: ...8 dBµV max 17 20 MUX VHF 3 dB less than UHF RF output adjustment FM 0 20 dB VHF UHF common 0 20 dB VHF UHF each channel 3 dB RF test 30 dB Powering DC feeding VHFIII UHF1 12 V 100 mA per input OFF ON for external VHFIII UHF2 Power consumption 230 V 50 60 Hz 6 W General Return loss 10 dB Operating temperature 200 C 500 C Dimensions Weight packed 192x147x55 mm 0 66 kg Recommended accessories 1 Power...

Page 5: ...ia 3 5 1 3 mm DC jack 12 1 V via RF output 12 1 V Current consumption 12 V 450 mA General Return loss 10 dB Operating temperature 200 C 500 C Dimensions Weight packed 100x147x55 mm 0 54 kg Technical characteristics This product complies with the relevant clauses of the European Directive 2002 96 EC The unit must be recycled or discarded according to applicable local and national regulations Equipm...

Reviews: