Programmable multiband amplifiers PA420T, PA321TP

Vers. 1.01

1

EN

Manual in .pdf 

P

roduct description

Programmable multiband amplifiers with digital filtering are designed to amplify DTT signals in the VHF and UHF bands and 

FM radio signals. These amplifiers have up to 20 programmable high selectivity digital filters for DTT with a wide individual 

AGC range and can be programmed to filter any VHF (170 ... 230 MHz), UHF (470 ... 694 MHz) channel.

The amplifiers are also characterized by easy installation, a wide input level range, high selectivity, low power consumption, 

high output level, output test point and LED indication (see Installation section). Each of the 20 filters allows to balance 

adjacent channels due to high selectivity. Channels are automatically aligned according to the programmed UHF output 

level and equalizer value. VHF channels will be adjusted according to the programmed UHF output level, the FM input has 

a programmable gain control. DC power is provided through certain DTT inputs (switchable), see Specification.

The series consist of:

PA420T has 3 DTT inputs (2xVHF/UHF and 1xUHF) with 5G LTE filtering and 1 FM input. It has its own power supply.

PA321T has 2 DTT inputs (VHF/UHF) with 5G LTE filtering and 1 FM input. It has two powering modes:
 

- via DC IN (DC jack) from external 12 V DC power supply;

 

- via RF output from suitable receiver or 12 V DC power supply using power inserter.

The housing of amplifiers meets more stringent screening requirements according to EN50083-2, class A.

The amplifiers are intended for indoor use only.

 

S

afety instructions

Installation of the amplifiers must be done according to IEC60728-11 and national safety standards.

The amplifier PA420T is powered from mains 230 V~. This voltage is dangerous to life. 

The amplifier PA420T is double isolated from the mains 230 V~.

The amplifier PA321TP is powered from the external stabilized power 12 V DC. This voltage is not dangerous to life.

Any repairs must be done by skilled personnel. 

Do not remove the cover of the power supply section, without disconnecting the unit from the mains supply. 

Do not plug the amplifier into the mains supply if the power cord or plug is damaged.

Do not plug the amplifier into the mains supply until all cables have been connected correctly.

The mains socket must be easily accessible.

The amplifier shall not be exposed to dripping or splashing water.

Avoid placing amplifier next to central heating components, near highly combustible materials and in areas of high humidity.

If the amplifier has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before plugging 

it into the mains.

Do not insert any objects into ventilation openings.

The ventilation should not be impeded by covering the amplifier with items, such as newspapers, table-cloths, curtains.

Mount the amplifier on not flammable wall or in not flammable installation box in vertical position with power supply unit on 

the right side. Mount in locations where children not likely to be present.

From top, front and bottom of installed amplifier must be at least 10 cm free space.

MONTAGE VIEW

Mount the amplifier on the vertical position with power supply unit on the right side. The amplifier must be fixed with steel 

screws Ø 4-5 mm. The screws are not included in a package.

IMPORTANT WARNINGS!

 

Before connecting any products to a system, it is essential to make sure the 

system power supply is switched off

. Avoid 

short-circuit or overload of any power supply. Never “HOT-SWAP” any system components as this may result in damage to 

the newly introduced or existing components.

Scan for downloading TERRnet App

from Google Play:

Summary of Contents for PA420T

Page 1: ...ge is dangerous to life The amplifier PA420T is double isolated from the mains 230 V The amplifier PA321TP is powered from the external stabilized power supply 12 V DC This voltage is not dangerous to life Any repairs must be done by skilled personnel Do not remove the cover of the power supply section without disconnecting the unit from the mains supply Do not plug the amplifier into the mains su...

Page 2: ...t F type 5 RF OUT RF signal output connector combined DTT and FM inputs F type 6 TEST 30 dB RF output signal test point F type 7 Control programming port 8 Adjust adjust LED green 9 Error error LED red 10 power cord 11 functional ground clamp 12 mounting supports Figure 1 External view of the amplifier PA420T 1 3 2 5 4 6 7 8 9 10 11 12 position of control port 7 12 ...

Page 3: ...ted marked Meet EN 55022 class B conducted emissions requirements measuring with grounded load Installation and configuration instructions Read the safety instruction first Fit amplifier on mounting place and connect all necessary RF cables connect 75 Ω loads to the unused F sockets power on amplifier Adjust green and Error red LED s blinking simultaneously briefly Adjust LED light up after that A...

Page 4: ...8 dBµV max 17 20 MUX VHF 3 dB less than UHF RF output adjustment FM 0 20 dB VHF UHF common 0 20 dB VHF UHF each channel 3 dB RF test 30 dB Powering DC feeding VHFIII UHF1 12 V 100 mA per input OFF ON for external VHFIII UHF2 Power consumption 230 V 50 60 Hz 6 W General Return loss 10 dB Operating temperature 200 C 500 C Dimensions Weight packed 192x147x55 mm 0 66 kg Recommended accessories 1 Power...

Page 5: ...ia 3 5 1 3 mm DC jack 12 1 V via RF output 12 1 V Current consumption 12 V 450 mA General Return loss 10 dB Operating temperature 200 C 500 C Dimensions Weight packed 100x147x55 mm 0 54 kg Technical characteristics This product complies with the relevant clauses of the European Directive 2002 96 EC The unit must be recycled or discarded according to applicable local and national regulations Equipm...