4.0

 

Maintenance 

 
Terra  Universal’s  work  stations  are  designed  for  low-maintenance  needs  for  the  entirety  of  the  unit’s  operational 

lifetime.    With  no  user-serviceable  parts,  these  unites  only  require  periodic  cleaning  to  preserve  their  like-new 
condition. 
 

Terra’s Glove Boxes require minimal maintenance.  All materials are easy to clean with water or mild detergent and a 
dry, clean wipe.  

 
All materials are easy to clean with clean, lukewarm water with or without a mild, non-abrasive detergent and a dry, 
clean non-abrasive wipe. Use only light pressure when cleaning. If the outside surface is exceptionally dirty or gritty, 

lightly swab the surface with a saturated cloth and allow the surfactants to drain away. Avoid rubbing dirt or grit into 
the surface. Turn the cloth often and replace with a clean cloth frequently. Dry the surface by blotting gently with a 
clean, dry cloth. 

 

Summary of Contents for 310 Series

Page 1: ... Document No 1788 10 Series 310 Glove Box Copyright 2017 Terra Universal Inc All rights reserved Revised February 2017 Terra Universal Inc TerraUniversal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 ...

Page 2: ... Series 310 Stainless Steel Glovebox features reinforced 12 gauge stainless steel construction with continuous seal welds to support vacuum inert gas backfill cycling that quickly removes atmospheric oxygen and moisture Radius corners offer superior sealing and easy cleaning A tempered safety glass window and fluorescent light provides visibility of the work area Proprietary Notice This manual per...

Page 3: ...hamber to provide a safe practical way of moving materials into and out of the work area Materials are loaded into the air lock by means of an external door an operator then opens an internal door inside the glove box to bring materials into the work area The standard air lock features its own gas inlet system pressure and an Automatic RB Valve port in case your application requires air lock purgi...

Page 4: ...lication the glove box is shipped with a conduit flange to allow easy conduit connection 1 Close the vacuum valves located on the top of the glove box 2 Connect exhaust conduit to the conduit flange The standard flange is for 6 diameter hosing 3 Connect the other end of the conduit to Terra s remote filter blower module The filter blower module should be equipped with a purification activated char...

Page 5: ...led ready for operation In ductless applications it includes an activated charcoal filter to remove organic fumes A final HEPA filter can be included to remove particulates for use in a cleanroom Vacuum line Solenoid valve line Power 110 or 220 Sensor Wire safety vacuum relief Vacuum Controller Vacuum Bleed Valve Negative Pressure Air Lock Vacuum Sensor Vacuum Shut Off Valve Solenoid Valve Vacuum ...

Page 6: ...box Use of Vacuum Controller requires factory installation of vacuum sensor inside the glove box or air lock 1 Connect the vacuum line to one of the vacuum fittings on top of the enclosure Open this valve and close the other which is used only to bleed the vacuum Open the vacuum shut off valve located near the solenoid 2 Make the connections as shown in the illustration 3 Set the vacuum set point ...

Page 7: ...r requires factory installation of sensor inside the antechamber 1 Connect the vacuum line to the antechamber Open the valve leading to the solenoid vacuum shut off valve and close the valve leading to the chamber which is used to bleed the vacuum 2 Make the connections as shown in the illustration 3 Set the vacuum set point on the Vacuum Controller at the desired vacuum level Always close the man...

Page 8: ...solenoid valve thereby isolating the vacuum pump When the pressure falls below the vacuum pressure set point the control module opens the solenoid valve allowing the pump to evacuate the chamber To adjust the vacuum set point on the Hasting 760 vacuum controller 1 Turn power switch on 2 Push the program button and down arrow momentarily 3 Sp1 will flash 4 Using the up and down arrows adjust to des...

Page 9: ...ic cleaning to preserve their like new condition Terra s Glove Boxes require minimal maintenance All materials are easy to clean with water or mild detergent and a dry clean wipe All materials are easy to clean with clean lukewarm water with or without a mild non abrasive detergent and a dry clean non abrasive wipe Use only light pressure when cleaning If the outside surface is exceptionally dirty...

Page 10: ...rately For Terra s Policy and Procedures for Returning Goods see Terra s Internet site www TerraUniversal com Generally customers can improve the chance of collecting on a freight claim by following these procedures 1 formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition 2 notifying the carrier upon discovery of concealed damag...

Reviews: