Terra Electronics SA91L Manual Download Page 2

2

MONTAGE VIEW

Mount the amplifier SA91L in vertical position with power supply unit on the right side. The multiswitch

 

must be fixed with 

steel screws Ø 4-5 mm. The screws are not included in a package.

up position

up position

down position

down position

SA91L

SA91DL

A  H,Lo

A  H,Lo

B H,Lo

B H,Lo

18V

18V

14V

14V

14V

14V

18V

18V

A H,Hi

A H,Hi

B H,Hi

B H,Hi

A V

,

Lo

A V

,

Lo

B V,Lo

B V,Lo

A V,Hi

A V,Hi

B V,Hi

B V,Hi

Terr.TV

Terr.TV

Slope dB

Slope dB

Slope dB

Slope dB

Slope dB

Slope dB

Slope dB

Slope dB

Slope dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

12 8 4 0

12 8 4 0

7 5 3 0

7 5 3 0

7 5 3 0

7 5 3 0

7 5 3 0

7 5 3 0

7 5 3 0

7 5 3 0

18 12 6 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

12 8 4 0 

12 8 4 0 

12 8 4 0

12 8 4 0

12 8 4 0

12 8 4 0

12 8 4 0

12 8 4 0

DC 12V Terr.TV in

OK

DC 18V 

H,Lo/H,Hi out

V,Lo/V,Hi out

DC 

14V 

Off

On

Off

On

Off

On

OK

OK

Overload

Overload

Overload

SAT amplifier SA91L

Frequency range   SAT  TV

Gain SAT TV

Frequency range  Terr. TV
Gain Terr. TV

DC output current

18V  

   

   

1.8

A

14V

    

    0.

5

A

12V  

  

    0.1A

950-2400 MHz

22 dB    

47-

790

 MHz

22 dB

 

55 W max.

230V 

50

 

/ 60Hz

Gain controls

Slope controls

Functional 

grounding clamp

Inputs

Outputs

12V switch and indicator

14V switch and indicator

18V switch and indicator

Mounting 

supports

Mounting 

supports

Mounting 

supports

Mounting 

supports

A  H,Lo

A  H,Lo

B H,Lo

B H,Lo

18V

18V

14V

14V

14V

14V

18V

18V

A H,Hi

A H,Hi

B H,Hi

B H,Hi

A V

,

Lo

A V

,

Lo

B V,Lo

B V,Lo

A V,Hi

A V,Hi

B V,Hi

B V,Hi

Terr.TV

Terr.TV

Slope dB

Slope dB

Slope dB

Slope dB

Slope dB

Slope dB

Slope dB

Slope dB

Slope dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

Att. dB

12 8 4 0

12 8 4 0

7 5 3 0

7 5 3 0

7 5 3 0

7 5 3 0

7 5 3 0

7 5 3 0

7 5 3 0

7 5 3 0

18 12 6 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

3 2 1 0

12 8 4 0 

12 8 4 0 

12 8 4 0

12 8 4 0

12 8 4 0

12 8 4 0

12 8 4 0

12 8 4 0

DC 12V Terr.TV in

OK

DC 18V 

H,Lo/H,Hi out

V,Lo/V,Hi out

DC 

14V 

Off

On

Off

On

Off

On

OK

OK

Overload

Gain controls

Slope controls

Functional 

grounding clamp

Inputs

Outputs

12V switch and indicator

14V switch and indicator

18V switch and indicator

Frequency range   SAT  TV
Gain SAT TV
Frequency range  Terr. TV
Gain Terr. TV

Power consumption from 18V

DC pass through        H lines

                                   V lines

5 W max

2 A max

0.5 A max

950-2400 MHz

22 dB    

47-

790

 MHz

22 dB

 

SAT amplifier SA91DL

18V

AUX

1Amax

Auxiliary 

DC input

Mounting 

supports

Mounting 

supports

Mounting 

supports

Mounting 

supports

Summary of Contents for SA91L

Page 1: ...ins 230 V this voltage is dangerous to life and SA91DL from line 12 20 V DC through input connectors or auxiliary DC input Any repairs must be done by a skilled personnel Amplifier SA91L is double isolated from mains 230 V To avoid the electric shock follow these instructions Do not remove the cover of the power supply section without disconnecting the amplifier from the mains supply Do not plug t...

Page 2: ...in controls Slope controls Functional grounding clamp Inputs Outputs 12V switch and indicator 14V switch and indicator 18V switch and indicator Mounting supports Mounting supports Mounting supports Mounting supports A H Lo A H Lo B H Lo B H Lo 18V 18V 14V 14V 14V 14V 18V 18V A H Hi A H Hi B H Hi B H Hi A V Lo A V Lo B V Lo B V Lo A V Hi A V Hi B V Hi B V Hi Terr TV Terr TV Slope dB Slope dB Slope ...

Page 3: ...ifier SA91DL is powered from central network power supply for example SA91L through horizontal polarization lines Both lines regarding DC are interconnected to minimize voltage loss in lines It consumes up to 0 3 A from 18 V power supply Amplifier has connector for auxilary power supply if voltage from central power supply is not accessible If it is plugged voltage is distributed to horizontal pol...

Page 4: ...02 96 EC The unit must be recycled or discarded according to applicable local and national regulations The device has integrated LTE filter Equipment intended for indoor usage only Equipment is double insulated from the mains with functional earthing Functional earthing Connect to the main potential equalization This product is in accordance to following norms of EU EMC norm EN50083 2 safety norm ...

Page 5: ...h elementów pasywnych zdefiniowanej w normie EN50083 2 Zgodnie ze standardem ETSI EN 303 354 V 1 1 1 typ wzmacniacza Launch klasyfikacja selektywności 0 INSTRUKCJE BEZPIECZEŃSTWA Montaż urządzeń powinien odbywać się zgodnie z obowiązującymi standardami bezpieczeństwa oraz być wykonywany przez wykwalifikowany personel Wzmacniacz SA91Lzasilany jest napięciem zmiennym 230 V Napięcie to jest niebezpie...

Page 6: ... przełącznik i wskaźnik Regulacja wzmocnienia Korekcja ch ki tłumienia przewodu Podpory montażowe Podpory montażowe Podpory montażowe Podpory montażowe A H Lo A H Lo B H Lo B H Lo 18V 18V 14V 14V 14V 14V 18V 18V A H Hi A H Hi B H Hi B H Hi A V Lo A V Lo B V Lo B V Lo A V Hi A V Hi B V Hi B V Hi Terr TV Terr TV Slope dB Slope dB Slope dB Slope dB Slope dB Slope dB Slope dB Slope dB Slope dB Att dB ...

Page 7: ... wzmocnienia dla najwyższych większe wzmocnienie i najniższych mniejsze wzmocnienie częstotliwości Wzmacniacz SA91L zapewnia zasilanie 18 V na wszystkich liniach sygnałowych polaryzacji poziomej 14V na wszystkich liniach polaryzacji pionowej oraz 12 V w torze wejściowym telewizji naziemnej Przełączniki umieszczone po stronie wyjść pozwalają na włączanie oraz wyłączanie napięcia na wyjściach urządz...

Page 8: ...nas Lithuania tel 370 37 31 34 44 fax 370 37 31 35 55 E mail sales terraelectronics com http www terraelectronics com SCHEMAT PRZYKŁADOWEJ INSTALACJI MV916L Ground Floor 1st Floor 2nd Floor MV912L SA91DL SD910 SD910 SD910 MV908L SA91L ...

Reviews: