27
5. Up: press
the key to increase temperature and timing set value.
6. Fan: press the
key to select high, low wind speed.
7. Sleep Mode: Press
the key to turn on the sleep mode.
PROTECTIONS
3.1 Frost Protection Function:
In cooling, dehumidifying or economic power saving mode, if the temperature of the exhaust
pipe is too low, the machine will automatically enter protection status; if the temperature of
the exhaust pipe rises to a certain temperature, it can automatically revert to normal
operation.
3.2 Overflow Protection Function:
When water in the water pan exceeds the warning level, the machine will automatically sound
an alarm, and the "FULL" indicator light will flash. At this point, you need to move the
drainage pipe connecting the machine or the water outlet to sewer or other drainage area to
empty the water (details see
Drainage Instruction
s at the end of this chapter). After the water
is emptied, the machine will automatically return to the original state.
3.3 Automatic Defrosting (cooling models have this function):
The machine has automatic defrosting function.
3.4. Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting protection
function after the compressor is turned off.
DRAINAGE
1. Manual drainage:
1) When the machine stops after the water is full, turn off the machine power and unplug the
power plug.
Notes: Please move the machine carefully, so as not to spill the water in the water pan at the
bottom of the body.
2) Place the water container below the side water outlet behind the body.
3) Unscrew the drainage cover and unplug the water plug, the water will automatically flow
into the water container.