TMS-UT-0416-T01-0
Page 6
Following figure shows the recommended minimal distances.
Figure 5 - Minimal distances for installing the boiler
It is possible to reduce recommended minimal distances, but the following requirements must
be met:
Power supply connection, located at bottom of boiler must be accessible
Bottom part of boiler must be accessible to allow change of heater
Control panel on bottom side of boiler must be accessible
Basic air circulation must be maintained.
3.3.2. Power supply
The boiler is rated as a high-power appliance and fixed wiring must be used. Please observe
chapter
about fuse and conductor requirements. When connecting the appliance to the
fixing wiring the means for disconnection (MCB) must be incorporated in fixed wiring in
accordance with the local wiring rules.
RCCB (RCD) switch 0,03A sensitivity is fitted inside a boiler.
Note:
In some cases, additional measures must be taken, subject to the requirements of the Local
Authorities.
3.4. System requirements
3.4.1. Pipe work
Pipe work that is not a forming part of the useful heating surface should be insulated to help
prevent heat loss and possible freezing, particularly where pipes are run through roof spaces
and ventilated under floor spaces. Draining taps must be located in accessible positions,
which permit the draining of the whole system including the boiler and the hot water system.
3.4.2. Cleansing and flushing the system
Flushing of system is highly recommended this will prevent damage to the appliance made
by dirt from the system.