supply, the burner will be extinguished and after the black-out is over, it will continue its operation
automatically.
The power consumption of the burner is in the range of a light bulb, except when ignition takes place
- then it can reach up to 300W. The ignition itself cannot take longer than 15 minutes. All technical
parameters and values mentioned above are preset by the factory, but the authorized person can change
them on the spot.
Important notes:
1. To turn on/o hold the corresponding button for 3 seconds.
2. Main switch should be always turned on - during the heating season.
3. Manual feed button is situated on the side of the burner and it is important that burner is lled
with pellets before start.
6.3 Using conventional solid fuel
6.4 Circulation Pump Thermostat
Boiler is equipped with a thermostat for the system circulation pump. The thermostat threshold can
be set on certain value and only when the temperature is higher than that, the circulation pump will be
turned on.
This thermostat is primarily used when ring with solid fuel, in order to prevent the low temperature
of the return line which can lead to condensation as a consequence. As the heating up process with wood
pellets is usually much faster compared to conventional wood, the eect of condensation should not take
place at all when burning pellets. The default value for temperature threshold is set at 60
◦
C. When
ring pellets the threshold should be at lower value, some 20
◦
C below the desired water temperature.
12