1 Boiler design and properties
1. Upper door for placing wood-logs 2. Secondary air inlet (manual regulation) 3. Lower door for cleaning
4. Primary air regulation 5. Thermostatic draught regulator 6. Chain for air regulation 7. Connectors for
safety heat exchangers 8. Connection for excess water outlet 9. Sensor placement 10. Flue box 11. Flue 12.
Secondary ue (ap) 13. Secondary ue ap handle 14. Opening for cleaning the ue box 15. Fill/Drain tap
16. Return 17. Base 18. Flow
1.1 Dimenzije
Type IGNIS Weight (kg) A
(mm)
B
(mm)
C
(mm)
D
(mm)
E
(mm)
F
(col)
G
(mm)
H
(mm)
I
(mm)
L
(mm)
IGNIS 20
320
726
648
468
480
200
2
490
1220 900
845
IGNIS 30
340
736
858
578
590
200
2
660
1220 900
1045
IGNIS 40
350
736
1135 578
590
200
2
860
1220 900
1245
1.2 Technical properties according to EN 303-5
Nominal power IGNIS (KW)
20
30
40
Power range (KW)
15-20
20-30
30-40
Necessary draught (mbar)
25
25
28
Water content (l)
45
60
70
Flue gases temperature (at nominal power) (
◦
C) 200
200
200
Heating chamber volume (dm3)
50
80
100
Mass ow at nominal power (kg/s)
0,016
0,021
0,045
Electrical network (V/Hz)
230/50
230/50
230/50
IP Protection
30
30
30
Temperature regulation range (
◦
C)
60-90
60-90
60-90
Min. temperature of the return line (
◦
C)
60
60
60
Eciency
76%
76%
75%
Boiler class
2
2
2
2
Summary of Contents for IGNIS