29
Declaration of Performance
TT23-CPR-2020-Version 1
Product:
Product type/application: Room heater burning solid fuel without hot water supply
Type:
TT23RG: S01-560
TT23RGS: S01-570
Fuel:
Wood
Productions no.
Please see nameplate on the back of the oven
Manufacturer:
TermaTech A/S
E-mail:
Gunnar Clausens Vej 36
Web:
www.termatech.com
8260 Viby J
Tel.:
+45 8742 0035
Denmark
Certification and requirements:
AVCP system:
System 3
European standard:
CE/DS/DIN/EN 13240:2001 + A2 :2004/AC2007
Certification:
Technologic Institute,
notified body no. 1235, has performed determination of the
product type and declared performance on the basis of type testing and issued test
report no. TI
300-ELAB-2517-EN
.
Declared performance:
The undersigned is responsible for the manufacturing and conformity with the declared performance.
Viby 02.09.2020
Søren Toft______________________________
Essential characteristics
Performance
Harmonised technical
specification
Reaction to fire
AI
CE/DS/DIN/EN
13240:2001+
A2 :2004/AC2007
Distance to combustible materials
Rear: min. 100 / 50 mm
Sides: min. 700 / 700 mm
To the corner 45⁰ min.
520 / 490 mm
Other safety distances
–
please see the User
and mounting manual
Emission of combustion products CO = 0,067%
NOx = 108 mg/m³
OGC = 47 mgC/Nm³
PM = 7 mg/m³
Electrical safety
NPD
Maximum operating pressure
NPD
Risk of burning fuel falling out
Passed
Surface temperature
Passed
Clean ability
Passed
Mechanical strength
Passed
Emission of hazardous materials
Passed
Flue gas temperature
247° Celsius
Output
5,6 KW
Energy efficiency
81 %