TERMA KTX 1 User Manual Download Page 5

 

6.  Put the radiator back in an upright position and check the level of the liquid inside it.

7.  Make sure that the connection between the radiator and the heating element is tight.

8.  Install the controller – fit the indents on the head (A) with the indents in the  

controller (B).

9.  Position the controller casing in a way providing an easy and comfortable access. 

WARNING!

 If you feel resistance when twisting the controller it means that you have 

reached the maximum twisting span in that direction. Try to twist the controller in the 

opposite direction. Any damage to the device will result in annulment of the warranty.

 

10.  Secure the casing at the back with Allen key.

11.  Connect the device to electricity and turn on the heating element unit (upper col-

lector opening must be open!). One can use a hot heating agent of temperature not 

exceeding 65°C. In such case, fill the entire radiator, put it in an upright position and 

turn the heating element unit on!!

12.  Set the maximum possible temperature required and observe the liquid level rise – 

the excess liquid may be slopping through the upper opening – remove excess liquid 

in order not to allow for the controller to be flooded or wetted. 

13.  When the level of the heating agent stops rising, wait another 5 minutes, turn off the 

heating element unit and disconnect the device from electricity.

14.  Do not wait until the radiator cools down and pour a small amount of the liquid out – 

to the mid level of the top pipe.

15.  Close the upper opening of the collector with a dedicated seal and put it back  

on the wall.

16.  Connect the heating element unit to the socket/installation. The device is ready to 

work. 

DUAL FUEL RADIATOR:

 

1.  Radiator connected to the central heating system to which heating element unit  

is installed additionally. 

2.  Central heating installation must be fitted with the valves enabling disconnecting the 

radiator from the rest of the system.

3.  Temperature of the heating agent from the central heating system inside the radiator 

must not exceed 82°C!

4.  It is recommended to bleed the radiator after every longer interval in use. The device 

has a thermal fuse built in which protects the radiator from operating in dry condi-

tions. Activation of thermal fuse means that the heating element unit will have to be 

returned to the Producer for servicing (not covered by warranty).

5.  Heating element must not be installed horizontally or turned downwards.

Tools required for installation of heating element unit.

– Allen key 1.5 (included)

– spanner no 24

Summary of Contents for KTX 1

Page 1: ...tric Heating KTX 1 KTX 2 KTX 3 KTX 4 Gebrauchsanweisung Elektroheizpatrone KTX 1 KTX 2 KTX 3 KTX 4 Mode d emploi Kit r sistance lectrique KTX 1 KTX 2 KTX 3 KTX 4 N vod na obsluhu Topn t leso KTX 1 KTX...

Page 2: ...not open the casing 9 Heating element s electric output cannot exceed 100 heating output of the radiator for the following parameters 75 65 20 C 10 Pressure inside the radiator must not exceed the pre...

Page 3: ...off switch Electric supply 230 V 50 Hz Heating output available 120 200 300 400 600 800 1000 W Device protection class Class I Radiator connection G 1 2 Casing protection mark IPx4 for MS IPx5 for PB...

Page 4: ...he below instructions 4 Other methods of correct filling of radiator can be found on www termaheat pl Radiator should not be filled with a heating agent of temperature higher than 65 C 5 Heating eleme...

Page 5: ...troller to be flooded or wetted 13 When the level of the heating agent stops rising wait another 5 minutes turn off the heating element unit and disconnect the device from electricity 14 Do not wait u...

Page 6: ...tion and bleed it 6 Make sure that the connection between the radiator and the heating element unit is tight 7 Install the controller fit the indents on the head A with the indents in the control ler...

Page 7: ...24 MAINTENANCE 1 Disconnect the device from electricity prior to cleaning 2 Heating element control head should be cleaned with a dry or damp cloth with a very small amount of detergents which should...

Page 8: ...teristics of the heating agent cause that the bottom pipes especially the two at the very bottom of the radiator may have a lower temperature than the remaining parts of the radiator this is a normal...

Page 9: ...ile the device is on the device will turn off after 2 hours 2 TIMER Mode can also be used to TURN the device ON Turn the device off using the button press the button the device will turn on after 2 ho...

Page 10: ...turns itself on and off periodically using only as much energy as it is required to maintain the set temperature of the radiator for current external conditions ANTI FREEZE FUNCTION When the device i...

Page 11: ...to deactivate the Timer press the button for a while use the arrows to set the Timer to OF and press again the device will switch to the Manual Mode During the Timer operation Dryer Mode can also be...

Page 12: ...ator icon icon indicating connection to a transmitter Heating element unit heats the radiator that it is installed in and precisely controls its temperature at the same time Buttons and are used to re...

Page 13: ...eading Press and hold the button the display panel will show letter E followed by 4 digits separated by a hyphen actual operating time of the device ie E 0 2 1 5 means that the device was actually wor...

Page 14: ...g signal the device will automatically return to remote operation PROBLEM SOLVING Problem Possible cause Solution Device is connected to electricity LED display panel is empty Connection problem Check...

Page 15: ...e to incorrect not in accordance with the manual installation use or disassembly incorrect use of the heating element ie for any purpose that is not specified by the Manufacturer as intended for this...

Page 16: ...TERMA Sp z o o Czaple 100 80 298 Gda sk Poland tel 48 58 694 05 00 fax 48 58 694 05 06 terma termagroup pl www termagroup pl MPGKE 92...

Reviews: