Caution
•
Take full care of fall and tumbling down during transportation. An
INJURY
is feared.
•
Lift up the Ring Blow equipped with a hanger bolt always after getting rid of
loosening of the hanger bolt. But after mounting the Ring Blow on a machine, do
not lift up the entire machine using the mounted hanger bolt.
Verify the mass of motor based in the nameplate, package box, outline drawing,
catalog or the like before lifting it and do not lift any more mass than the rated load
of lifting tool. The gravity center of the Ring Blow is located at motor side, therefore,
the Ring Blow inclines to one side during lift-up.
Exert tension gradually on the wire and do not lift up suddenly.
This lift-up work may only be executed by the qualified workers. Do not stay under
the Ring Blow during the lifting work.
An
INJURY
or
FIRE
caused by
FALL
or
TUMBLING DOWN
is feared for all of
these cases
.
Transportation
•
Ambient temperature should be kept –20
℃~
+60
℃
during transportation.
•
Open the package after verifying the top and bottom of product. An
INJURY
is
feared.
Opening the
Package
•
Open the wooden frame package taking care of the used nails. Wear glove when
opening the wooden package. An
INJURY
is feared.
•
Verify if the product is just the ordered one. An
INJURY
,
DAMAGE
or a
FIRE
due
to use of the incorrect product is feared.
•
Never place any inflammable material around the Ring Blow. A
FIRE
is feared.
•
Do not place any obstacle against ventilation around the Ring Blow. A
BURN
or a
FIRE
caused by abnormal heating due to disturbed cooling is feared.
•
Fasten the foundation bolts surely.
Insufficient fastening may cause an
INJURY
and
DAMAGE
due to shift of the Ring
Blow.
Installation,
Adjustment
•
Never get on or hang on the Ring Blow. An
INJURY
is feared.
•
Ring Blow shell be always mounted on suitable place in order to see its nameplate
easily and do not put any obstacle in front of it.
Do not dismount the nameplate.
•
Construct the piping and wiring according to the technical standard for electrical
equipment and the internal wiring provisions. A
BURNOUT
or a
FIRE
is feared.
•
For wiring to the terminal base in terminal box, fasten the terminal screws with a
torque of 1.0 to 1.3 N
・
m. Otherwise,
DAMAGE
of the terminal box is feared.
•
For measuring the insulation resistance, do not touch the terminal. An
ELECTRIC
SHOCK
is feared.
Piping,
Wiring
•
No protection unit belongs to the Ring Blow except for some models. The installing
of overcurrent protection unit is obliged based upon the technical standard for
electrical equipment. For preventing a
FIRE
and
DAMAGE
due to a motor burnout,
we recommend to install the protection unit other then overcurrent protection units
(including a ground fault interrupter) based upon consulting with us.
•
If any abnormality occurs, stop the operation immediately and switch off the power
supply. An
ELECTRIC SHOCK
an
INJURY
or a
FIRE
is feared.
•
The Ring Blow becomes considerably hot during its operation. Take care not to
touch it by your hand or body. A
BURN
is feared.
Operation
•
Do not insert your finger or any others material into the opening of Ring Blow. An
ELECTRIC SHOCK
an
INJURY
or
FIRE
is feared.
•
Wear stopples during operation to shut the big noise.
3