Page 1: ...2018 Terafence Ltd All rights reserved Terafence MBsecure Installation and Configuration Manual PN PartNumber TBD 001...

Page 2: ...ols 3 TF_MBsecure solution diagram 4 Solution Highlights 4 MBsecure Panels 5 Front Panel 5 Rear Panel 5 MBsecure Installation 6 What s in the box 6 Installing MBsecure 6 Configuring MBsecure 8 Technic...

Page 3: ...CADA protocols are communications protocols designed for the exchange of control messages on industrial networks Over the past three decades several hundred of these protocols have been developed for...

Page 4: ...eloped by Enron Corporation with support for 32 bit integer and floating point variables and historical and flow data Data types are mapped using standard addresses The historical data serves to meet...

Page 5: ...The information does not relate directly to issues that might cause injury to patients or users or damage to the system CAUTION A caution provides information relating to issues that might cause inju...

Page 6: ...Highlights PLC is secure from attacks at OSI Layer 1 physical link MODBUS data is collected from PLC and made available for HMI PLC read poll command interval is configurable for maximum accuracy Nea...

Page 7: ...The 4 LEDs between the traffic indicators show the data flow direction through the device regardless of actual traffic Hard Reset switch for restoring factory settings Press and hold for 10 seconds Fi...

Page 8: ...Ethernet cables not provided with the device 3 Connect a computer to the same network switch 4 Configure the computer Ethernet port settings to a IP address 192 168 1 3 b Subnet MASK 255 255 255 0 5...

Page 9: ...B at IP address 192 168 1 2 but you can ping Module B to verify connectivity 7 Log in using the following credentials User Name Admin Password admin 8 Once logged in you will see MBsecure configuratio...

Page 10: ...ess MBsecure Module A LAN Port Module A IP Address to communicate with PLC Device ID MBsecure Module B MBsecure MODBUS device ID as configured in the HMI application PLC Device ID PLC MODBUS ID design...

Page 11: ...as required on site NOTE It is recommended to capture a screen shot at this point to document the configuration CAUTION MBsecure default configuration Module IP addresses is set as 192 168 1 1 for Mo...

Page 12: ...ING ON THE DATE OF INITIAL PURCHASE PROVIDED THAT THE PRODUCTS WAS UNDER NORMAL USE AND PROPER HANDLING PURCHASERS WILL BE ENTITLED TO REPAIR OR REPLACEMENT OF DEFECTIVE UNITS TO OBTAIN WARRANTY SERVI...

Page 13: ...thernet PLC TCP IP Port PLC PLC TCP Port to access for data HMI IP Address Main HMI Main computer Only HMI from this address will be served All other requests will be dropped HMI IP Address Backup HMI...

Page 14: ...Start Read Holding Registers Set the first HOLD Register number to read HOLD Register Number Read Holding Registers HOLD Registers range Number on consecutive HOLD Registers to read INPUT Register St...