ENC-400-HDMI
™ H.264 Encoder
User Guide V 2.1
26
3.4.5
Menu: Encoder / SDT
The Service Description Table (SDT) describes services that are contained in a particular transport
stream. Such services are the service name and the service provider. The ETSI EN 300 468 standard
contains a detailed information about SDT.
Figure 16: Encoder / SDT page of the ENC-
300™ encoder
describes the ‘Encoder / SDT’ page of the ENC-300™.
Settings:
Description:
Periods [ms]:
Specifies the time period in milliseconds, how often the service
description table shall be inserted into the transport stream. The
value ‘0’ disables the insertion.
Original Network Id:
Specifies the network identifier of the originating delivery system.
The value range is: 1
– 65535. But the range of 65281 – 65535 is
for private temporary use.
.!.
We recommend using the range for private temporary
use.
Service Name:
Specifies the name of the service.
Service Provider:
Specifies the provider name of the service.
Table 10: Description of the 'ENCODER/SDT' webpage of the ENC-
300™