6.

 

Powering 

TCW181B-CM

 is designed to be supplied by adapter SYS1421-0612-W2E or similar, intended 

for use in the conditions of overvoltage category II, and priorly assessed for compliance with safety 
requirements. The power supply equipment shall be resistant to short circuit and overload in 
secondary circuit. 

When in use do not position the equipment so that it is difficult to disconnect the device from 

the power supply. 

 

7.

 

Environment information  

This equipment is intended for use in a Pollution Degree 2 environment, at altitudes up to 

2000 meters. 

When the controller is a part of a system, the other elements of the system shall comply with 

the EMC requirements and shall be intended for use in the same ambient conditions. 

 

8.

 

Safety 

This device must not be used for medical, life saving purposes or for any purpose where its 

failure could cause serious injury or the loss of life. 

To reduce the risk of fire, only flexible stranded wire, with cross section 0.5mm² or larger for 

wiring of digital and analog inputs and relay output of the device should be used.  

To avoid electric shock and fire hazard, do not expose this product to liquids, rain, or 

moisture. Objects filled with liquids, such as vases, should not be placed on this device. 

There is a risk of overheating (damage) of controller, if recommended free spaces to adjacent 

devices are not ensured. Joint part with external component shall have space for 
attachment/removal of the cable after installation. 

Teracom does not guarantee successful operation of the product if the product was used 

under conditions deviating from the product specifications. 

To ensure that the device works correctly follow the steps below: 

 

ensure that the devices are installed correctly, refer this user manual; 

 

log in to the devices via browser program; 

 

make proper set up; 

 

set up the digital inputs to work in “dry contact” mode; 

 

short the “DI” and “GND”; 

 

Switch on “Monitoring page” of WEB interface – proper value for digital input should be 
displayed in the same time 

Sts

 led should flashes; 

 

When you push the button “All On”, all relays should be activated and all relay’s status 
LED’s should be constantly shine. 

If the equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired. 

In no event will Teracom Ltd. be responsible or liable for indirect or consequential damages 

resulting from the use or application of this equipment. 

 

9.

 

Maintenance 

Upon completion of any service or repairs to the device or once per year, safety check must 

be perform to determine that this product is in proper operating condition. 

Clean the device only with dry cloth. Do not use a liquid cleaner or an aerosol cleaner. Do not 

use a magnetic/static cleaning device (dust remover) or any kind of abrasive materials to clean the 
device. 

 

Summary of Contents for TCW181B-CM

Page 1: ...ut is suitable for solving specific problems in various fields such as remote control process automation home automation and others 2 Features 10 Mb Ethernet connectivity Password protected web based configuration and control 1 digital input with logic level and dry contact modes 8 relays with NO and NC contacts SNMP v 1 support Sending SNMP Traps messages under certain conditions Sending E mail m...

Page 2: ...NO COM NC of Relay7 Pin 10 11 12 NO COM NC of Relay8 Connector 2 Pin 1 2 3 NC COM NO of Relay4 Pin 4 5 6 NC COM NO of Relay3 Pin 7 8 9 NC COM NO of Relay2 Pin 10 11 12 NC COM NO of Relay1 Connector 3 Pin 1 Digital input DI Pin 2 Ground Pin 3 12VDC Connector 4 Power Ø2mm central positive Connector 5 Ethernet RJ45 Operating mode is selected by jumper DI on PCB closed for dry contact and open for log...

Page 3: ...ler if recommended free spaces to adjacent devices are not ensured Joint part with external component shall have space for attachment removal of the cable after installation Teracom does not guarantee successful operation of the product if the product was used under conditions deviating from the product specifications To ensure that the device works correctly follow the steps below ensure that the...

Page 4: ...for mechanical details Maintain spacing from adjacent equipment Allow 50 mm of space on all sides as shown on fig 2 in Appendix A This provides ventilation and electrical isolation 11 Configuration Please follow the steps below for proper installation 1 Mount the controller in a dry and ventilated place 2 Connect the Ethernet port to a 10 100MB Ethernet network For direct connection to a PC use a ...

Page 5: ... to login the following message appears Someone s logged in The active session will be terminated automatically if the current user stays inactive for 2 minutes 11 2 Monitoring page After successful authorization the Monitoring page appears The Monitoring page provides information about the state of the relays and digital input ...

Page 6: ...P address is static DNS these fields is mandatory if domain names are used instead of IP addresses By default DNS has the same Ip address as Default gateway Time Server and Time Zone these fields are not mandatory they are used when e mail must be sent Host Name up to 16 symbols it appears as a Subject in sent e mails MAC device MAC address The good practice is to change the default IP address of ...

Page 7: ...ings for SNMP section are SNMP Configuration enable disable SNMP Read Write community performs client authentication Read Only community performs client authentication SNMP Traps enable disable SNMP trap messages IP address IP address of the receiving host Community string performs client authentication Trap Interval time interval in seconds for SNMP trap messages Max Traps number maximum number o...

Page 8: ...put can mange e mail sending Following parameters must be set Mail to e mail address of recipient Subject e mail subject Message e mail body Important It is necessary to set SMTP server settings on Network Setup page to successfully send e mail messages In the example above if an event occurs closing contact the controller will send e mail message to info teracom cc with subject input alarm and bo...

Page 9: ...Network Management Protocol This could be done using every SNMPv 1 compatible program Parameters that can be changed are grouped according to their functions in the tables below To obtain a valid OID number it is necessary to replace the x symbol with the 1 3 6 1 4 1 38783 To save the changes configurationSaved OID x 6 0 should be set to 1 13 1 Product OID Name Access Description Syntax x 1 1 0 na...

Page 10: ...7 pulse state INTEGER 0 255 x 3 17 0 Pulse8 read write Relay 8 pulse state INTEGER 0 255 x 3 18 0 allOn read write Set all relays On INTEGER 0 255 x 3 19 0 allOff read write Set all relays Off INTEGER 0 255 x 3 20 0 allPulse read write Pulse all relays INTEGER 0 255 13 4 Network OID Name Access Description Syntax x 4 1 0 deviceIPAddress read write Device IP address IpAddress x 4 2 0 subnetMask rea...

Page 11: ...SIZE 0 22 x 6 0 configurationSaved read write Configuration save status SAVED UNSAVED INTEGER SAVED 1 UNSAVED 0 x 7 0 restartDevice read write Restart Device INTEGER RESTART 1 CANCEL 0 14 XML and HTTP API commands XML is often preferred choice when it comes to M2M communication and system integration The monitored values are transmitted in status xml file that can be easily processed by software a...

Page 12: ... Name Admin admin Password Admin admin IP Address 192 168 1 2 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 1 SNMPConfiguration disabled readCommunity public writeCommunity private 16 Firmware update TCW181B CM supports remote firmware update To update the device follow the steps below Download the TCW1XX_Update_Tool program from www teracom cc Download the latest firmware version file cod f...

Page 13: ...TCW181B CM_R1 Page 13 Appendix A Fig 1 Fig 2 ...

Reviews: