11.Firmware update 

TCW180 

supports remote firmware update. To do this please follow the steps below: 

 

-

 

Download the latest firmware version from  

www.teracom.cc

 . The extension of 

the update file is .cod .  

-

 

Open Command Prompt window. In the example below in 

blue

 are the 

commands that must be entered, and in 

red

 are the descriptions of these 

commands : 

 

 

C:\>  --  

go to the directory where the update file is located ( .cod extension)

 

C:\>

ftp 212.73.154.53

   

--  

FTP connection to the controller is made

  

Connected to 212.73.154.53.  

220 Ready  

User (212.73.154.53:(none)): 

admin

  -- 

enter username

  

331 Password required  

Password: 

*****

      -- 

enter password 

230 Logged in  

ftp> 

put tcw180v1.00.cod

   --  

the update file is sent for update

  

200 Ok  

150 Transferring data...  

150 DON’T UNPLUG POWER CABLE FOR NEXT 2 MINUTES!!!    – 

2 minutes after this message 

appears, the device will be successfully updated 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

ftp: 157822 bytes sent in 60.89Seconds 2.59Kbytes/sec 

ftp> 

 
 
 
 
 
 

Rev . 1 – May, 2011 

 

 

DO NOT TURN OFF THE POWER SUPPLY DURING THESE 2 MINUTES! 

TURNING OFF THE POWER SUPPLY WILL DAMAGE THE DEVICE! 

Summary of Contents for TCW180

Page 1: ...s suitable for solving specific problems in various fields such as remote control process automation home automation and others 2 Features 10 Mbit Ethernet connectivity Password protected web based co...

Page 2: ...ltage V 2 5 Maximum low level input voltage V 0 8 Maximum input voltage for digital input V 5 5 Max switchable current at 220 VAC 3 Max switchable voltage VAC VDC 250 110 4 Connectors Inputs and outpu...

Page 3: ...ller through web interface Link green this LED is located on the Ethernet connector It indicates that the device is connected to the network Act yellow this LED is located on the Ethernet connector It...

Page 4: ...on the same network for example 192 168 1 3 To get access to the web interface of the controller you should type the following URL into the browser http 192 168 1 2 If the network settings are correc...

Page 5: ...tton is pressed the relay will change its state for the time specified in the Pulse Duration field in the I O Setup page Three buttons are located on the bottom of the page All ON clicking this button...

Page 6: ...s at the same time It may be necessary to clear the arp cache each time you connect new device to the network This is done by typing arp d in the command prompt of a Windows computer In order to reduc...

Page 7: ...ient authentication SNMP trap messages are sent for the following conditions if event occurs on Digital Input the signal changes its state device restart The following parameters can be changed SNMP T...

Page 8: ...Pulse button on Monitoring page This setting applies to all 8 relays TCW180 can be set to send e mail alerts if an event occurs onthe digital input The following fields should be filled Mail to recip...

Page 9: ...Access Description Syntax x 3 1 digitalInput read only Digital input state INTEGER High 1 Low 0 x 3 2 Relay1 read write Relay 1 state INTEGER ON 1 OFF 0 x 3 3 Relay2 read write Relay 2 state INTEGER O...

Page 10: ...d write SMTP Sender e mail address String SIZE 0 39 9 5 I O Setup OID Name Access Description Syntax x 5 1 0 relayPulseDuration read write Global Pulse duration INTEGER 0 255 x 5 2 0 Relay1description...

Page 11: ...e the power supply from the unit press and hold the RESET button then turn on the power supply wait about 5 seconds and release the RESET button The factory default settings are shown in the table bel...

Page 12: ...ension C ftp 212 73 154 53 FTP connection to the controller is made Connected to 212 73 154 53 220 Ready User 212 73 154 53 none admin enter username 331 Password required Password enter password 230...

Reviews: