TCW122B-RR_R2.4 -March 2019
Page 4
The controller supports one active session – only one user can operate the device over the WEB
interface. If another user tries to login, the message “Someone is logged in” appears:
The active session will stay open until the "Monitoring" page is open. Inactivity on other pages
or closing the browser without logoff will terminate the session automatically in 4 minutes.
8.2.
Monitoring page
The “Monitoring” page provides information about the state of the relays, digital inputs and
the status of connection:
8.3.
General setup page
8.3.1.
“Local setting”
•
Device mode
– “Client” or “Server”. The “Client” initiates communication, “Server” just
responds to the “Client” messages.
•
Device ID –
this is information field. The value can be used for extra communication
filtering – see “Client settings”;
•
Encryption key -
the communication between devices is always encrypted. When the
field is empty - default key, stored in the ROM of the device, is used. All devices have
the same default key.