13.

 

Environment information  

This equipment is intended for use in a Pollution Degree 2 environment, at altitudes up to 2000 

meters. 
When the controller is a part of a system, the other elements of the system shall comply with the 

EMC requirements and shall be intended for use in the same ambient conditions. 

14.

 

Safety 

This device must not be used for medical, life-saving purposes or for any purpose where its failure 

could cause serious injury or the loss of life. 
To reduce the risk of fire, only flexible stranded wire, with cross section 0.5mm² or larger for wiring 

of digital inputs and relay outputs of the device should be used.  
To avoid electric shock and fire hazard, do not expose this product to liquids, rain, or moisture. Do 

not expose this product to dripping or splashing liquids, rain, or moisture. Objects filled with 

liquids, such as vases, should not be placed on this device. 
There is a risk of overheating (damage) of the controller, if recommended free spaces to adjacent 

devices are not ensured. The joint  part with external component shall have space for 

attachment/removal of the cable after installation. 
Teracom does not guarantee successful operation of the product if the product was used under 

conditions deviating from the product specifications. 

To ensure that the system (two devices) works correctly follow the steps below: 

 

ensure that the devices are installed correctly, refer this user manual; 

 

log in to the devices via browser program; 

 

make proper set up for client and server devices; 

 

the yellow LED’s of both devices blink, if they are “in connection”;  

 

set up the digital inputs to work in “dry contact” mode; 

 

short the digital input of ”client” device – appropriate relay of “server” device should 
be activated; 

 

short the digital input of ”server” device – appropriate relay of “client” device should 
be activated. 

If the equipment is used in a manner not specified by the manufacturer, the protection provided 

by the equipment may be impaired. 
In no event will Teracom Ltd. be responsible or liable for indirect or consequential damages 

resulting from the use or application of this equipment. 

15.

 

Maintenance 

Upon completion of any service or repairs to the device or once per year, safety check must be 

performed to determine that this product is in proper operating condition. 
Clean the device only with dry cloth. Do not use a liquid cleaner or an aerosol cleaner. Do not use 

a magnetic/static cleaning device (dust remover) or any kind of abrasive materials to clean the 

device. 

 

 

Summary of Contents for TCW122B-RR

Page 1: ......

Page 2: ... relays with NO and NC contacts Encrypted communication protocol Device ID filtering Manual or DHCP network configuration Removable terminal connectors separated for inputs and outputs Autonomous operation Remote firmware update 3 Specifications Physical characteristics Dimensions 107 x 72 x 32 mm Weight 110 g Environmental limits Operating тemperature range 20 to 55 C Storage temperature range 25...

Page 3: ...n1 NC Relay1 Connector 4 Pin2 COM Relay1 Connector 4 Pin3 NO Relay1 Connector 5 Pin1 NC Relay2 Connector 5 Pin1 COM Relay2 Connector 5 Pin1 NO Relay2 Operating mode is selected by jumper DI1 DI2 closed for dry contact and open for logic level By default jumpers are closed 5 LED indicators The following indicators show the status of the controller Relay1 Relay2 green these LEDs are illuminated when...

Page 4: ...ion and electrical isolation 8 Configuration Please follow the steps below for proper installation 1 Mount the controller in a dry and ventilated place 2 Connect the Ethernet port to a 10 100MB Ethernet network For direct connection to a PC using a crossover cable 3 Connect the I O pins of the controller according to the required application 4 Connect the power supply If the red LED STS blinks the...

Page 5: ...minutes 8 2 Monitoring page The Monitoring page provides information about the state of the relays digital inputs and the status of connection 8 3 General setup page 8 3 1 Local setting Device mode Client or Server The Client initiates communication Server just responds to the Client messages Device ID this is information field The value can be used for extra communication filtering see Client set...

Page 6: ...anages corresponding relays of the Client Server IP Port network settings of Server It is mandatory that port here should be the same like in field Port on Server device Connection interval time in seconds in which the Client sends a request to Server In case of input activation the Client sends the request immediately doesn t matter how many seconds are passed from the previous regular request Th...

Page 7: ...devices are connected to the Internet Both devices have with public IP addresses For Server device the IP address should be static 9 2 Both devices are connected to one LAN Both devices have private addresses For Server device the IP address should be static 9 3 Client is connected to LAN and Server is connected to the Internet Client device has a private IP address valid default gateway should be...

Page 8: ...es and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Teracom Ltd cannot assume responsibility or liability for actual use based on the examples and diagrams 10 1 Single direction remote control TCW122B RR allows device control at a remote location In the example alarm button connected...

Page 9: ...he input of one device switches on the relay in the opposite device and vice versa 10 3 One Client to many Servers In Multi servers mode one Client communicates with up to 6 Servers Activating the input of Client switches on the corresponding relay of all Servers Only the digital inputs of Server1 switch on the relays of Client ...

Page 10: ...in admin IP Address 192 168 1 2 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 1 12 Firmware update TCW122B RR supports remote firmware update To update the device follow the steps below Go to www teracomsystems com and download the latest firmware version file from TCW122B RR product page Go to the device login page enter a username and password and press the Login button Go to Update menu s...

Page 11: ...om does not guarantee successful operation of the product if the product was used under conditions deviating from the product specifications To ensure that the system two devices works correctly follow the steps below ensure that the devices are installed correctly refer this user manual log in to the devices via browser program make proper set up for client and server devices the yellow LED s of ...

Page 12: ...TCW122B RR_R2 4 March 2019 Page 11 Appendix A Fig 1 Fig 2 ...

Page 13: ...TCW122B RR_R2 4 March 2019 Page 12 ...

Reviews: